Table 29: YV28 to YV50 VFD four-stage standard static with modulating power exhaust
Comp. 1
Comp. 2
Comp. 3
Min
disconnect
rating
Min
disconnect
rating/120V
trans
Size
(tons)
Nominal
unit
voltage
RLA LRA RLA LRA RLA LRA
OD fan
motors
each
FLA
OD fan
motors
each
FLA
Supply
blower
motor
FLA
Supply
blower
motor
LRA
Power
exhaus
t VFD
FLA
Power
exhaus
t motor
LRA
120 V
trans
FLA
MCA
A
Max
f/b
size
A
FLA
LRA
MCA
with
120 V
trans
A
Max
f/b
size
with
120V
trans
A
FLA
LRA
208-3-60 41.0 304 22.4 149 22.4 149
4.0
21.0
22.0
144.4
9.6
21.0
14.4
144
175
153
872
158
175
170
887
230-3-60 41.0 304 22.4 149 22.4 149
4.2
21.0
22.0
144.4
9.6
21.0
13.0
144
175
154
872
157
175
169
885
460-3-60 19.2 147 10.6 75 10.6 75
2.1
10.5
11.0
72.2
4.8
10.5
6.5
69
80
74
432
76
90
82
439
YV28
(27.5)
575-3-60 16.7 122 7.7
54
7.7
54
1.6
7.8
9.0
59.1
4.9
7.8
5.2
57
70
60
336
62
75
66
341
208-3-60 44.2 315
25
164
25
164
4.0
21.0
22.0
144.4
9.6
21.0
14.4
153
175
163
913
167
200
180
928
230-3-60 44.2 315
25
164
25
164
4.2
21.0
22.0
144.4
9.6
21.0
13.0
154
175
164
913
167
200
179
926
460-3-60 22.4 158 12.8 100 12.8 100
2.1
10.5
11.0
72.2
4.8
10.5
6.5
78
100
83
493
84
100
91
500
YV30
(30)
575-3-60 18.6 136 9.6
78
9.6
78
1.6
7.8
9.0
59.1
4.9
7.8
5.2
63
80
67
398
68
80
73
403
208-3-60 48.1 351 27.6 191 27.6 191
4.0
21.0
22.0
144.4
9.6
21.0
14.4
163
200
174 1003 177
225
190 1018
230-3-60 48.1 351 27.6 191 27.6 191
4.2
21.0
22.0
144.4
9.6
21.0
13.0
164
200
174 1003 177
200
189 1016
460-3-60 24.7 197 12.8 100 12.8 100
2.1
10.5
11.0
72.2
4.8
10.5
6.5
81
100
86
532
87
110
93
539
YV35
(35)
575-3-60 22.4 135 9.6
78
9.6
78
1.6
7.8
9.0
59.1
4.9
7.8
5.2
68
80
71
397
73
90
77
402
208-3-60 48.1 351 27.6 191 27.6 191
4.0
21.0
28.0
173.44
15.2
39.6
14.4
175
200
187 1070 189
225
203 1084
230-3-60 48.1 351 27.6 191 27.6 191
4.2
21.0
28.0
173.44
15.2
39.6
13.0
175
200
188 1070 188
225
203 1083
460-3-60 24.7 197 12.8 100 12.8 100
2.1
10.5
14.0
86.72
8.2
19.8
6.5
87
110
93
565
94
110
101
572
YV40
(40)
575-3-60 22.4 135 9.6
78
9.6
78
1.6
7.8
11.0
71.77
6.1
15.8
5.2
71
90
75
426
76
90
81
431
208-3-60 67.3 485 39.1 267 39.1 267
7.2
39.6
28.0
173.44
15.2
39.6
14.4
234
300
250 1430 249
300
267 1444
230-3-60 67.3 485 39.1 267 39.1 267
6.8
39.6
28.0
173.44
15.2
39.6
13.0
233
300
248 1430 246
300
263 1443
460-3-60 32.7 215 18.6 142 18.6 142
3.4
19.8
14.0
86.72
8.2
19.8
6.5
114
125
122
705
120
150
129
711
YV50
(50)
575-3-60 26.3 175 15.4 103 15.4 103
2.7
15.8
11.0
71.77
6.1
15.8
5.2
92
110
98
548
97
110
104
553
Installation Manual: YORK
®
Sun™ Select YV28 to YV50
51
Johnson Controls Ducted Systems
Summary of Contents for Sun Select YV28
Page 2: ...Tested in accordance with ...
Page 105: ...Installation Manual YORK Sun Select YV28 to YV50 105 Johnson Controls Ducted Systems ...
Page 106: ...Installation Manual YORK Sun Select YV28 to YV50 106 Johnson Controls Ducted Systems ...
Page 107: ...Installation Manual YORK Sun Select YV28 to YV50 107 Johnson Controls Ducted Systems ...
Page 108: ...Installation Manual YORK Sun Select YV28 to YV50 108 Johnson Controls Ducted Systems ...
Page 109: ...Installation Manual YORK Sun Select YV28 to YV50 109 Johnson Controls Ducted Systems ...