![background image](http://html1.mh-extra.com/html/york/r-410a/r-410a_technical-and-service-manual_3503981297.webp)
Controller
___________________________________________________________________________________
- 296 -
3. ENC2 (NUM_S)
―
Number Setting (for outdoor)
The present address setting has been put outside the electric control board for convenient
setting. The range is 0-F. Before indoor units are power on, the address setting must be finished
and the address setting of indoor units that match with the same outdoor unit can’t be repeated,
or it may cause compressor jumping-down, indoor EXV can’t open, indoor fan motor jumping-
down, and so on. After finishing address setting, indoor units must be power on again and
address setting must be checked again to ensure no repeated setting. The checking method is
as follows: press the button on the display board for 5 seconds, the display board will display
address setting, continue to press for 5 seconds, the display board will display power setting.
The setting is as follows:
Operation
lamp
Timer lamp
Defrosting lamp
Alarm lamp Communication Address
Indoor kW
OFF OFF OFF OFF
0
2.2 kW
OFF OFF OFF ON
1 2.8
kW
OFF OFF ON OFF
2
3.6
kW
OFF OFF ON
ON
3 4.5
kW
OFF
ON
OFF OFF
4
5.6
kW
OFF
ON OFF ON
5 7.1
kW
OFF
ON
ON OFF
6
7.2
kW
OFF
ON
ON
ON
7 9.0
kW
ON OFF OFF OFF
8
11.2
kW
ON OFF OFF ON
9 14.0
kW
ON OFF ON OFF
10
ON OFF ON
ON
11
ON
ON OFF OFF
12
ON
ON OFF ON
13
ON
ON
ON OFF
14
ON
ON
ON
ON
15
OFF OFF OFF OFF
16
2.2 kW
OFF OFF OFF Flash
17 2.8
kW
OFF OFF Flash OFF
18
3.6
kW
OFF OFF Flash
Flash 19 4.5
kW
OFF
Flash OFF OFF
20
5.6
kW
OFF
Flash OFF Flash
21 7.1
kW
OFF
Flash
Flash OFF
22
7.2
kW
OFF
Flash
Flash
Flash
23 9.0
kW
Summary of Contents for R-410A
Page 103: ...Wall mount 102 Part 4 2 Wall Mounted...
Page 113: ...Wall mount 112 4 Dimensions 4 1 YDS 22 36EC 4 2 YDS 45 56EC...
Page 115: ...Wall mount 114 5 Piping Diagrams 5 1 YDS 22 56EC 5 2 YDS 22 56HC...
Page 116: ...Wall mount 115 6 Wiring diagrams 6 1 YDS 22 36EC 6 2 YDS 45 56EC...
Page 117: ...Wall mount 116 6 3 YDS 22 56HC...
Page 118: ...Wall mount 117 7 Sound level 7 1 Test condition 7 2 Noise spectrums YDS 22 36EC HC...
Page 119: ...Wall mount 118 YDS 45 56EC HC...
Page 120: ...Wall mount 119 8 Velocity temperature distribution Discharge angle 70...