![YOKOGAWA YTA510 User Manual Download Page 36](http://html1.mh-extra.com/html/yokogawa/yta510/yta510_user-manual_3838199036.webp)
<7. Setting Parameters>
7-3
IM 01C50E01-01EN
7.3.2 Function Block and Menu Tree
(1) Function Block
The function of this transmitter is shown below. A specific function might not be able to be used according to
the field wireless configuration tool used. When the field wireless configuration tool of our recommendation is
used, the software attached to the Field Wireless Integrated Gateway is necessary for setting the dotted line
part.
Refer to Subsection 8.2 “Calibration Instruments Selection” for the field wireless configuration tool of our
recommendation.
• Configuration
• Diagnostics
• Alerts
• Power Status
• Identification
(UAPMO)
(UDO)
• Configurationn
• Others
(CO)
• UAPMO
• UDO
• CO
• TRANSDUCER
• AI1/AI2 Temp
Online Menu
• UAP Option
• Hardware Write Protect
• Static Revision
• Reset Energy Left
• Radio Silence
• Energy Harvest Type
(Configuration)
• Diagnostic Status
• Diagnostic Status Detail.1
• Diagnostic Status Detail.2
• Diagnostic Switch
• Diagnostic Configuration
(Diagnostics)
• Version Revision
• CTS Version
• ITS Version
• Identification Number
(Identification)
(APP Download)
(Configuration)
(Others)
(COMM_ENDPOINT)
(COMM_CONTRACT)
(PUB_ITEM)
(Alerts)
F0702-1.ai
• Energy Left
• Power Supply Status
• Power Supply Voltage
(Power Status)
• APP Download
• DESCRIPTION
• STATE
• MAX_BLOCK_SIZE
• LAST_BLOCK_DOWNLOADED
• ERRER_CODE
• COMM_ENDPOINT
• COMM_CONTRACT
• PUB_ITEM_MAX
• PUB_ITEM_NUM
• PUB_ITEM
• REVISION
• Network address of remote endpoint
• Transport layer port at remote endpoint
• Object ID at remote endpoint
• Stale data limit
• Data publication period
• Ideal publication phase
• PublishAutoRetransmit
• Configuration status
• ContractID
• Contract_Status
• Actual_Phase
• ObjectID
• AttributeID
• AttributeIndex
• Size
• Other Faults Alert
• Faults Non-compliance Alert
• Faults Process Influence Alert
• Simulation Active Alert
• Soft Update Incomplete Alert
• Power Low Alert
• Power Critical Low Alert
• Fault Prediction Alert
• Environmental Conditions Alert
• Outside Sensor Limits Alert
• Out of Service Alert
• Calibration Problem Alert
• Faults Sensor or Actuator Alert
• Faults Electronics Alert