<2. Notes on Handling>
2-1
IM 01C50E01-01EN
2. Notes on Handling
The YTA temperature transmitter is fully factory-
tested upon shipment. When the YTA is delivered,
check the appearance for damage, and also
check that the transmitter mounting parts shown
in Figure 2.1 are included with your shipment. If
“No Mounting Bracket” is indicated, no transmitter
mounting bracket is included.
U-bolt nut
Horizontal pipe
mounting bracket
Vertical pipe
mounting bracket
Bracket
fastening bolt
Spring washer
Bracket
fastening nut
Transmitter
fastening bolt
Spring washer
Transmitter
fastening bolt
Spring washer
U-bolt
U-bolt
F0201.ai
No antenna is provided for Amplifier
housing code 9.
Antenna
Figure 2.1
Transmitter Mounting Hardware
2.1 Check the Model Name and
configuration
The model name and configuration are indicated
on the nameplate. Verify that the configuration
indicated in the “Model and Suffix Code” in Chapter
10 is in compliance with the specifications written
on the order sheet.
: Refer to USER'S MANUAL.
Made in Japan
TOKYO 180-8750 JAPAN
MODEL
SUFFIX
SUPPLY
OUTPUT
mA DC
V DC
STYLE
CAL
RNG
NO.
F0202.ai
TEMPERATURE
TRANSMITTER
Figure 2.2
Name Plate
2.2 Transport
To prevent damage while in transit, leave the
transmitter in the original shipping container until it
reaches the installation site.
2.3 Storage
When an extended storage period is expected,
observe the following precautions.
1. Choose a storage location that satisfies the
following requirements.
• A location that is not exposed to rain or water.
• A location subject to a minimum of vibration or
impact.
• The following temperature and humidity range
is recommended. Ordinary temperature and
humidity (25°C, 65%) are preferable.
Temperature:
–40 to 85°C
–30 to 80°C (LCD visible
range)
Humidity:
5 to 100% RH (at 40°C)
2. If at all possible, store the transmitter in
factory-shipped condition, that is, in the original
shipping container.
3. Preferably remove the batteries for storage. For
maximum battery life, the storage temperature
should not exceed 30°C