8 Output Assemblies (Drive Consumes)
40
YASKAWA
SIEP C730600 84G DeviceNet Technical Manual
Name
Description
External Fault
External Fault EF0
0: -
1: External Fault [EF0]
Fault Reset
Fault Reset
0: -
1: Fault Reset
Function Code
MEMOBUS/Modbus Function Code
Refer to
for information.
1000-Series, GA500: Multi-Function Digital
Output
GA700, GA800, FP605: Multi-Function Digital
Output 1
1000-Series, GA700, GA800, FP605: Terminal M1/M2
0: M1/M2 OFF
1: M1/M2 ON
GA500: Terminal MA/MB
0: MA/MB OFF
1: MA/MB ON
This function is enabled only when
H2-01 = F
.
1000-Series, GA500: Multi-Function Photocoupler
1
GA700, GA800, FP605: Multi-Function Digital
Output 2
1000-Series, GA500: Terminal P1
0: P1 OFF
1: P1 ON
GA700, GA800, FP605: Terminal M3/M4
0: M3/M4 OFF
1: M3/M4 ON
This function is enabled only when
H2-02 = F
.
1000-Series, GA500: Multi-Function Photocoupler
2
GA700, GA800, FP605: Multi-Function Digital
Output 3
1000-Series, GA500: Terminal P2
0: P2 OFF
1: P2 ON
GA700, GA800: Terminal P1
0: P1 OFF
1: P1 ON
FP605
0: MD/MF OFF
1: MD/MF ON
This function is enabled only when
H2-03 = F
.
Multi-Function Digital Output 4
Terminal P2
0: P2 OFF
1: P2 ON
This function is enabled only when
H2-04 = F
.
Speed Reference
Speed Reference
Sets drive speed reference.
Units are determined by parameter
o1-03 [Frequency Display Unit Selection]
.
Unit is not affected by Speed Scale SS.
Register Number
MEMOBUS/Modbus Register Number
Register Data
MEMOBUS/Modbus Register Data
*1
Terminals are different for different drive models. Refer to
Terminals that Change depending on the Model of the Drive on page 52
for more information.
*2
Multi-function digital output 4 is not available for 1000-Series, GA500, GA800, or FP605 drives.
*3
Register numbers 0x0001, 0x0002, and 0x0009 are disabled.
Note:
This is a paired assembly (105/155).
Table 8.4 Function Code Decode Table
Function Code
High Byte - Low Byte
MEMOBUS/Modbus Function
00
No Operation
10
Read Register
01
Write Register
11
No Operation
Note:
Refer to the MEMOBUS/Modbus Data Table in the drive Technical Manual for a list of monitor data using the MEMOBUS/Modbus
message area.