![YASKAWA SI-N3/V Technical Manual Download Page 24](http://html1.mh-extra.com/html/yaskawa/si-n3-v/si-n3-v_technical-manual_3203469024.webp)
24
YASKAWA
SIEP C730600 84G DeviceNet Technical Manual
6.
Use one of the remaining included screws (B) to connect the ground wire (A) to the ground terminal and
installation hole on the option.
Tighten the screw to a correct tightening torque:
• 0.5 N
∙
m to 0.6 N
∙
m (4.4 in
∙
lb to 5.3 in
∙
lb)
Note:
Refer to
for instructions about crimp terminal orientation (C) and wire routing.
A - Ground wire
B - Included screw
C - Crimp terminal
Figure 5.20 Connect the Ground Wire
7.
Firmly connect the DeviceNet communication cable to the option terminal block (CN1).
Isolate communication cables from main circuit wiring and other electrical and power lines. Make sure that
you firmly connect the cable end. (Refer to
). Refer to
Communication Cable Wiring on page
for more information.
NOTICE
Damage to Equipment. When you touch the option, make sure that you observe correct electrostatic
discharge (ESD) procedures. If you do not follow procedures, it can cause ESD damage to the drive circuitry.
8.
Reattach the drive front cover (A) and the keypad (B).
Refer to the drive manuals for more information.
NOTICE
Do not pinch cables between the front covers and the drive. Failure to comply could cause
erroneous operation.