No.
Description
4
Rated Output Current
Note:
Refer to the tables for the rated output current by model.
5
EMC noise filter
•
Three-Phase AC 200 V Class and 400 V Class
–
A: No internal EMC filter
–
B: Internal category C3 EMC filter
•
6-Phase/12-Pulse 400 V Class
–
A: No internal EMC filter
6
Enclosure protection design
•
Three-Phase AC 200 V Class and 400 V Class
–
A: IP00/UL Open Type
–
B: IP20/UL Open Type
–
W: IP55/UL Type 12 Heatsink External Mounting
•
6-Phase/12-Pulse 400 V Class
–
A: IP00/UL Open Type
–
W: IP55/UL Type 12 Heatsink External Mounting
7
Environmental specification
A: Standard
M: Humidity-resistant and dust-resistant
■
Rated Output Current
,
, and
give the rated output current values.
Note:
•
These output current values are applicable for drives that operate at standard specifications.
•
Derate the output current in applications that:
–
Increase the carrier frequency
–
Have high ambient temperature
–
Install drives side-by-side.
•
Use
C6-01 [Normal / Heavy Duty Selection]
to select Normal Duty rating (ND) or Heavy Duty rating (HD).
Table 4.2 Rated Output Current: Three-Phase 200 V Class
Model
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
(Default)
Maximum Applicable Motor
Output
kW (HP)
Rated Output Current
A
Maximum Applicable Motor
Output
kW (HP)
Rated Output Current
A
2004
0.55 (0.75)
3.5
0.75 (1)
4.2
2006
0.75 (1)
5
1.1 (1.5)
6
2008
1.1 (1.5)
6.9
1.5 (2)
8
2010
1.5 (2)
8
2.2 (3)
9.6
2012
2.2 (3)
11
3 (4)
12.2
2018
3 (4)
14
3.7 (5)
17.5
2021
3.7 (5)
17.5
5.5 (7.5)
21
2030
5.5 (7.5)
25
7.5 (10)
30
2042
7.5 (10)
33
11 (15)
42
2056
11 (15)
47
15 (20)
56
2070
15 (20)
60
18.5 (25)
70
2082
18.5 (25)
75
22 (30)
82
2110
22 (30)
88
30 (40)
110