YASKAWA
TOEPC71061737D GA800 DRIVE INSTALLATION & PRIMARY OPERATION
13
Model
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
(Default)
Maximum Applicable Motor
Output
kW (HP)
Rated Output Current
A
Maximum Applicable Motor
Output
kW (HP)
Rated Output Current
A
4930
525 (700)
810
600 (800)
930
4H11
600 (800)
930
675 (900)
1090
4H12
675 (900)
1090
750 (1000)
1200
Table 4.4 Rated Output Current: 6-Phase/12-Pulse 400 V Class
Model
Heavy Duty Rating (HD)
[C6-01 = 0]
Normal Duty Rating (ND)
[C6-01 = 1]
(Default)
Maximum Applicable Motor
Output
kW (HP)
Rated Output Current
A
Maximum Applicable Motor
Output
kW (HP)
Rated Output Current
A
T103
45 (60)
91
55 (75)
103
T140
55 (75)
112
75 (100)
140
T168
75 (100)
150
90 (125)
168
T208
90 (125)
180
110 (150)
208
T250
110 (150)
216
150 (200)
250
T302
150 (200)
260
185 (250)
302
T371
185 (250)
304
220 (300)
371
T414
220 (300)
371
260 (350)
414
T477
260 (350)
414
300 (400)
477
T568
300 (400)
477
335 (450)
568
T605
335 (450)
605
370 (500)
675
T720
370 (500)
605
450 (600)
720
5
Drive Specifications
Note:
•
To get the OLV, CLV, and AOLV specifications, do Rotational Auto-Tuning.
•
To get the longest product life, install the drive in an environment that meets the necessary specifications.
Table 5.1 Control Characteristics
Item
Specification
Control Methods
•
V/f Control
•
V/f Control with Encoder
•
Open Loop Vector
•
Closed Loop Vector
•
Advanced Open Loop Vector
•
PM Open Loop Vector
•
PM Advanced Open Loop Vector
•
PM Closed Loop Vector
•
EZ Vector Control
Carrier Frequency
•
Models 2004 to 2138, 4002 to 4103, and T103
HD: 8 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 15 kHz maximum.
•
Models 2169 to 2415, 4140 to 4414, and T140 to T414
HD: 5 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 10 kHz maximum.
•
Models 4477 to 4720, and T477 to T720
HD: 2 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 5 kHz maximum.