YASKAWA
TOEPC71061737D GA800 DRIVE INSTALLATION & PRIMARY OPERATION
163
Code
Name
Causes
Possible Solutions
Er-05
No-Load Current Error
The Auto-Tuning results were not in the applicable
parameter setting range.
Auto-Tuning did not complete in a pre-set length of
time.
•
Examine and repair motor wiring.
•
Disconnect the machine from the motor and do Rotational Auto-
Tuning again.
The motor nameplate data entered during Auto-
Tuning is incorrect.
•
Make sure that the input motor nameplate data is correct.
•
Do Auto-Tuning again and correctly set the motor nameplate
data.
Rotational Auto-Tuning was done with a load that
was more than 30% of the rating connected to the
motor.
•
Disconnect the machine from the motor and do Rotational Auto-
Tuning again.
•
If you cannot uncouple the motor and load, make sure that the
load is less than 30% of the motor rating. If a mechanical brake
is installed in the motor, release the brake during Rotational
Auto-Tuning.
Er-08
Rated Slip Error
The motor nameplate data entered during Auto-
Tuning is incorrect.
•
Make sure that the input motor nameplate data is correct.
•
Do Auto-Tuning again and correctly set the motor nameplate
data.
Auto-Tuning did not complete in a pre-set length of
time.
The Auto-Tuning results were not in the applicable
parameter setting range.
•
Examine and repair the motor wiring.
•
If the motor and machine are connected during Rotational Auto-
Tuning, decouple the motor from the machinery.
Rotational Auto-Tuning was done with a load that
was more than 30% of the rating connected to the
motor.
•
Disconnect the machine from the motor and do Rotational Auto-
Tuning again.
•
If you cannot uncouple the motor and load, make sure that the
load is less than 30% of the motor rating. If a mechanical brake
is installed in the motor, release the brake during Rotational
Auto-Tuning.
Er-09
Acceleration Error
The motor did not accelerate for the specified
acceleration time.
1.
Increase the value set in
C1-01 [Acceleration Time 1]
.
2.
Disconnect the machine from the motor and do Rotational
Auto-Tuning again.
The value of
L7-01 or L7-02 [Forward/Reverse
Torque Limit]
is small.
Increase the value set in
L7-01 or L7-02
.
Rotational Auto-Tuning was done with a load that
was more than 30% of the rating connected to the
motor.
•
Disconnect the machine from the motor and do Rotational Auto-
Tuning again.
•
If you cannot uncouple the motor and load, make sure that the
load is less than 30% of the motor rating. If a mechanical brake
is installed in the motor, release the brake during Rotational
Auto-Tuning.
Er-10
Motor Direction Error
There is defective drive and motor wiring.
Examine and repair motor wiring.
There is defective drive and encoder wiring.
Examine and repair the wiring to the encoder.
The direction of the motor and the setting of
F1-05
[PG 1 Rotation Selection]
are opposite.
Set
F1-05
correctly.
The machine pulled the motor to rotate in the
opposite direction.
When the torque reference is 100% or higher, the sign
of the speed reference was opposite of the detected
speed.
Disconnect the machine from the motor and do Rotational Auto-
Tuning again.
Er-11
Motor Speed Error
The torque reference during acceleration is too high
(100%).
•
Increase the value set in
C1-01 [Acceleration Time 1]
.
•
Disconnect the machine from the motor and do Rotational Auto-
Tuning again.
Er-12
Current Detection Error
There is a phase loss in the drive input power. (U/T1,
V/T2, W/T3)
Examine and repair motor wiring.
The current exceeded the current rating of the drive.
The output current is too low.
•
Check the motor wiring for any short circuits between the wires.
•
Check and turn ON any magnetic contactors used between
motors.
•
Replace the control board or the drive. For information about
replacing the control board, contact Yaskawa or your nearest
sales representative.
You tried Auto-Tuning without a motor connected to
the drive.
Connect the motor and do Auto-Tuning.
There was a current detection signal error.
Replace the control board or the drive. For information about
replacing the control board, contact Yaskawa or your nearest sales
representative.
Er-13
Leakage Inductance Alarm
The motor rated current value is incorrect.
Correctly set the rated current indicated on the motor nameplate and
perform Auto-Tuning again.
The drive could not complete tuning for leakage
inductance in fewer than 300 seconds.
Examine and repair motor wiring.