5
-54
U1-64
Current refer-
ence of q axis
Monitors the current reference of q axis. Motor rated current
0.1%
A
A
7FH
Iq Reference
U1-65
Current refer-
ence of d axis
Monitors the current reference of d axis. Motor rated current
0.1%
A
A
80H
Id Reference
U1-71
PG counter
value
Monitors the pulse counter from PG
(pulse generator or encoder).
65536
Pulse
−
A
86H
PG Counter
Value
U1-77
Output current
average
Monitors the average of an output cur-
rent integrated value.
(Addition time 40 minutes for the aver-
age.)
Inverter rated
output current
0.1 A
A
A
8CH
Output I Aver-
age
U1-78
Output voltage
Monitors the output voltage.
Voltage class
1 V
A
A
8DH
Output Voltage
U1-80
Error status 1
Inverter error status 1.
Low/High register is changed by the
digital operator [DATA/ENTER] key.
Lower register(L) status
High register(H) status
−
[Bit]
A
A
8FH
Error Sts 1
Constant
Number
Name
Description
100% Value
Min.
Unit
Control
Methods
MEMOBUS
Register
Display
Open-
loop
Vector
Flux
Vector
Not Used
Not Used
1: Motor overload (OL1)
Not used
1: Overtorque 1 (OL3)
1: Overtorque 2 (OL4)
Not Used
Not Used
0
0 0
0
0
0 0
0
1: Over speed (OS)
1: Speed deviation (DEV)
1: PG disconnection (PG0)
1: Output open-phase (LF)
1: Digital operator
connection fault (OPR)
1: EEPROM erro (ERR)
Not Used
Not Used
0
0 0
0
0
0 0
0