Wiring
3.4.4 Sequence Input Signal Circuit (for Stand-alone Drive)
3
-32
3.4.4 Sequence Input Signal Circuit (for Stand-alone Drive)
Design the input signals in consideration of the following conditions.
D
The 12-bit digital reference signals into the Inverter’s 1CN connectors and the sequence input signals
into 6CN connectors can be 0 V, 24 V, or external common signals. The wiring of terminals varies with
the input method as shown below.
D
To select the external common method, prepare a 24-V (20 to 26 V) power supply for the input signal.
D
The 1CN common and 6CN common terminals are insulated. Therefore, it is possible to used the com-
mon terminals individually.
D
If a relay contact is used, the minimum contact capacity must be 5 mA at 30 V.
D
There will be a signal delay of approximately 5 ms due to the input filter.
0 V Common
+24 V Common
External Common
+24 V (or 0 V)
0 V (or +24 V)
EXTCOM
24VCOM
0VCOM
3.3k
Ω
390
Ω
EXTCOM
24VCOM
0VCOM
3.3k
Ω
390
Ω
EXTCOM
24VCOM
0VCOM
3.3k
Ω
390
Ω
Signal Name
Pin Number
Signal Name
1CN
6CN
EXTCOM
31
19, 20, 21
24VCOM
32
22, 23
0VCOM
33
24, 25