10.1 User Constants
10
-5
Table 10.1
User Constants (continued)
Con-
stant
No.
Name
Explanation
Change
*
1
Unit Standard
Setting
Upper
Limit/
Lower
Limit
C1-38
Signal Selec-
tions 3
SEL3
*
4
Signal selections for control mode and level
S
Bits 1 and 0: Load meter filter selection
*
2
00: 2-ms filter
01: 10-ms filter
10: 100-ms filter
11: 500-ms filter
S
Bit 2: Torque limit auto judgement
0: Speed reference gain switching OFF
1: Speed reference gain switching ON
S
Bit 3: Sensitivity switching selection when using servo mode
*
2
0: Not judged
1: Judged
S
Bit 4: Excessive speed deviation protection (AL-32) operation threshold
0: 1/2 or less of speed reference
1: 1/4 or less of speed reference
S
Bit 5: Speed limiting level
*
2
0: 105% of rated reference
1: 110% of rated reference
S
Bit 6: Speed agree signal (AGR) output at zero speed
0: Output (AGR: closed)
1: Not output (AGR: open)
S
Bit 7: Load meter adjustment selection
*
2
0: 120% of rated output signal for 30 min.
1: 100% of continuous rated output signal
No
---
00000000
---
C1-39
Signal Selec-
tions 4
SEL4
*
4
Signal selections for control mode and level
S
Bit 0: Orientation control method
0: Encoder
1: Magnetic sensor
When the setting has changed, turn the control power supply OFF then
ON again.
No
---
00000000
---
C1-40
Signal Selec-
tions 5
SEL5
*
4
Control mode signal selections
S
Bit 1 and 0: Operation delay time for excessive speed deviation protec-
tion (AL-32)
00: 0 s
01: 0.3 s
10: 0.4 s 11: 0.5 s
S
Bit 2: Torque detection signal (TDET) output
0: Standard output
1: ON for acceleration/deceleration
S
Bit 3: NC orientation
0: Disabled.
1: Enabled. Even if orientation signal (ORT) is input, the
Inverter will not perform orientation. The rotating
direction of motor is determined according to the polar-
ity of speed reference.
S
Bit 4: Load meter output standard selection
*
2
0: Continuous rated output
1: 30 min. rated output
S
Bit 5: Servo mode speed reference gain selection (Enabled when bit 3 of
C1-38 is ON.)
*
2
0: Analog speed reference, 10 V/5,000 rotations/min.
1: Set the read gain of the analog speed reference using
C1-49 or C1-50.
S
Bit 7: Load fault detection selection (AL-33)
0: Disabled
1: Enabled
No
---
00000000
---
10