14.1 Drives
1
4
-7
Model CIMR-MR5
j
*
2
25P5
27P5
2011
2015
2018
2022
2030
Required Power Capacity (kVA)
9
12
19
24
30
36
48
Continuous Rated Input Current
(A)
13.3
19.7
26.8
39.3
53.6
66.1
78.6
Continuous Rated Output Current
(A)
17.6
26.2
35.7
52.4
71.4
88.1
104.8
Power Supply
Three-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to
−
15%, allowable frequency fluctuation:
±
5%,
Line-to-line voltage unbalance: 5% or less)
C
onverter
*
4
Control Power Supply
Single-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to
−
15%, allowable frequency fluctuation:
±
5%)
Required power capacity: 100 VA (for independent drive system)
250 VA (for NC system)
C
o
Control Method
Power regenerative control (120
_
current conduction)
Overload Capacity
120% for one minute, 200% for one second
oller
Approx. Mass
lb (kg)
11 (5)
27 (12)
35 (16)
ontro
Di
i
i i h
Width
3.94 (100)
5.91 (150)
7.84 (200)
Co
n
Dimensions in inches
(mm)
*3
Height
13.78 (350)
(mm)
*3
Depth
12.60 (320)
Power Supply AC Reactor Code
No.
X010058
X010059
X010060
X010061
X010062
X010063
X010064
Model CIMR-M5
j
*2
CIMR-MR5
j
*2
25P5
27P5
2011
2015
2018
2022
2030
Ambient Temperature
0
°
C to 55
°
C (32
°
F to 131
°
F) (not frozen)
n
Heatsink Intake Air Temperature
0
°
C to 45
°
C (32
°
F to 113
°
F)
mon
Storage Temperature
*5
−
20
°
C to 60
°
C (
−
4
°
F to 140
°
F)
C
om
m
Humidity
90% or less (non-condensing)
C
o
Location
Indoor (protected from corrosive gases and dust), elevation: 1000 m (3280 ft) or less
Vibration
9.8 m/s
2
(1G) at 10 to less than 20 Hz, up to 2 m / s
2
(0.2G) at 20 to 50 Hz
Protective Structure
IEC IP00
(Protected so that parts of the human body cannot reach electrically charged parts from the front)
* 1. Rated output power is guaranteed when input voltage is three-phase, 200 V (50/60 Hz), 220 V (50/60 Hz), 230 V (60 Hz). If
input voltage is lower than 200 V, rated output power is not guaranteed.
* 2. A: For stand-alone drive system N: for NC system
* 3. Dimensions of External Heatsink Cooling Type. Refer to
14.1.3 Dimensions
for Open Chassis Type.
* 4. An AC reactor is required between Converter and main circuit power supply.
* 5. Temperature during shipping.
14
Summary of Contents for CIMR-M5 Series
Page 12: ...Notes for Motor xi...