10.3 Magnetic Sensor Orientation Constants
10
-13
Table 10.3
Magnetic Sensor Orientation Constants (continued)
Con-
stant
No.
Name
Explanation
Change
*
1
Unit Standard
Setting
Upper
Limit/
Lower
Limit
C3 24
Orientation Control
Signal Selections 3
SEL-M3
*2
Orientation control parameters
S
Bits 5 and 4: Speed reference differential compensation gain
00: 10
01: 15
10: 20
11: 30
No
10000000
C3-24
11: 30
S
Bits 7 and 6: Flux level for positioning servo loop control
00: 100%
01: 80%
10: 60%
11: 40%
No
---
10000000
---
*1.
Change
(change during operation) column: Indicates whether the constant can be changed during inverter operation.
Yes: Constant can be changed during inverter operation; No: Constant cannot be changed during inverter operation
*2. In signal selection descriptions, 0 stands for “
” and 1 for “
.”
10