Wiring
3.4.3 Control Signal Functions
3
-30
Table 3.13
Control Circuit Signals (6CN)
Connector
Signal
No.
Function
Signal Level
Related Constants
+15V
1
+15V output
+15V Load current: 10mA or less
SS
2
Shield (0V)
−
C1-26 10 C1-38 bit 5
SCOM
3
Analog speed reference input
0 to
±
10V
(Input impedance: 50k
Ω
)
C1-26, 10, C1-38 bit 5
C1-11, 12
0V
4
Analog speed reference 0V
−
DAS
5
Digital/analog speed reference
selection
C1-36 bit 7
RDY
6
Operation ready
Selected when C1-37 bit 2=0
EMG2
6
Emergency stop 2
Selected when C1-37 bit 2=1
EMG
7
Emergency stop
−
FWD
8
Forward run
−
REV
9
Reverse run
−
TLH
10
Torque limit H
Selected when C1-36 bit 2=0
C1-26, C1-38 bit 2
TLL
11
Torque limit L
Selected when C1-36 bit 1, 0=00
INC
11
Incremental
Selected when C1-36 bit 1, 0=10
SSC
12
Soft start cancel
Selected when C1-36 bit 3=0
SV
12
Servo mode
24VDC
Selected when C1-36 bit 3=1
RST
13
Fault reset
24VDC
Current when closed: 5mA
−
CHW
14
Winding selection
Current when closed: 5mA
−
PPI
15
P control/PI control selection
Selected when C1-36 bit 4=0
ORT
16
Orientation
Selected when C1-40 bit 3=0
C1-39 bit 0
NCORT
16
NC orientation
Selected when C1-40 bit 3=1
LGR
17
L gear selection
C1 27 28 29
MGR
18
M gear selection
C1-27, 28, 29
EXT-
COM0
19 to 21 Sequence input signal power sup-
ply common
−
6CN
24VCOM
22, 23
Sequence input signal power sup-
ply 24V
−
0VCOM
24, 25
Sequence input signal power sup-
ply 0V
−
FC0
26
Fault code 0
FC1
27
Fault code 1
Open-collector output
FC2
28
Fault code 2
p
p
Exclusive-use for 24VDC
−
FC3
29
Fault code 3
Exclusive use for 24VDC
Load current: 50mA or less
COM2
30
Fault code signal common
Load current: 50mA or less
ZSPD
33
Zero-speed
C1-19
AGR
34
Speed agree
C1-20, C1-38 bit 6
SDET
35
Speed detection
C1-21, C1-22, C1-40 bit 2
TDET
36
Torque detection
C1-23
TLE
37
Torque limit
Open-collector output
−
ORG
38
Load origin
p
p
Exclusive-use for 24VDC
−
ORE
39
Orientation completion
Exclusive use for 24VDC
Load current: 50mA or less
C2-09, 10 or C3-09, 10
CHWE
40
Winding selection completion
Load current: 50mA or less
−
FLTL
41
Fault (OFF at fault)
−
TALM
46
Minor fault
−
COM1
42
Sequence output signal common
−
FLTNO
43
Fault contact output
Relay contact output
Exclusive-use for 24VDC
FLTNC
44
Fault contact output
Closed between 43 and 45 at fault
Exclusive-use for 24VDC
Load current: 1A or less
−
FLTCOM
45
Open between 44 and 45 at fault
Minimum permissible load: 10 mA
(as reference value)
SM
47
Speedometer output
0 to +10V Load current: 2mA or less
C1-16, 54
0V
48
0V for speedometer
−
−
LM
50
Load ratio meter output
0 to +10V Load current: 2mA or less
C1-17, 54, 18, C1-40 bit 4
C1 38 bit 1 0
0V
49
0V for load ratio meter
−
C1-38 bit 1, 0
C1-38 bit 7
Note: The 5CN connector is for M5A models for stand-alone drive.
3