33
6. Maintenance procedures
Daily inspection
/
care
Gas selector switch
GAS410 the maximum pressure within the compressor output is 0.1Mpa, if you need to use higher
pressure, please use the external N2 bomb gas.
1. Gas selector switch, select "Internal compressor".
2. Gas selector valve 90 degrees clock wise, make sure the direction of the arrow above the valve
handle. (Use N2 bomb pressure for Nozzle spray ).
Inside the door
Supply oil to the blower
Exchange lubrication oil after 500 hours of operation (about 20 days) of initial operation after installation
and each of about 2000 hours of operation (about three months) thereafter.
①
Remove the blind plates on the right side plate and at the lower right of the rear side.
②
Stop the blower, remove the oil drain plug, and allow all old oil to discharge.
③
Replace the plug, and fill new lubrication oil to the line of the oil gauge taking care dusts will not
enter at the upper oil filler port.
(
Approx.0.3L
)
Lubrication oil brands
Appropriate oil is additional turbine oil No.3 (#180) of JIS K2213 or equivalent. Typical brands are
as follows.
Mobil
Esso
Idemitsu Mitsubishi
Nisseki
Showa
Shell
Kyoseki
Cosmo
No. 3
DTE oil
heavy
medium
Teresso
68
Daphne
turbine
oil 68
Diamond
turbine oil
68
FBK
turbine
68
Turbo oil
T68
J-H oil68
Kyoseki
RIX
turbine
68
Cosmo
turbine
super 68
Gas alarm
Filter case
Oil filler port
Oil gauge
Oil drain plug
Flow meter for
introducing N2