56
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
●
Release Rate (Rl Rate)
Range: 0 — 63
For the Amplitude EG, this determines the Release rate of
the EG, or how long the level of the sound sustains after a
note is released. For the Filter and Pitch EGs, this deter-
mines how long it takes the tone/pitch to reach the EG
Release Level setting.
●
Initial Level (Int Lvl)
(Filter EG and Pitch EG only)
Range: -63 — +63
This determines the initial setting of the filter or pitch,
before the note is played.
●
Attack Level (At Lvl)
(Filter EG and Pitch EG only)
Range: -63 — +63
This determines the filter/pitch level setting that follows the
Initial Level.
●
Decay 1 Level (D1 Lvl)
Range: 0 — 127 (Amplitude EG)
-63 — +63 (Filter EG and Pitch EG)
For the Amplitude EG, this determines the level setting that
follows the maximum level reached at the end of the
Attack. For the Filter and Pitch EGs, this determines the
level setting that follows the Attack Level.
●
Decay 2 Level (D2 Lvl)
Range: 0 — 127 (Amplitude EG)
-63 — +63 (Filter EG and Pitch EG)
This determines the level setting that follows the Decay 1
Level.
NOTE: Regarding the Decay 1 and Decay 2 Level parameters,
Decay 2 can set to a higher value than Decay 1, yet the actual
levels of the two remain equal. (In other words, the actual level
of Decay 2 cannot be greater than that of Decay 1.)
●
Release Level (Rl Lvl)
(Filter EG and Pitch EG only)
Range: -63 — +63
This determines the final setting of the filter or pitch, after
the note is released.
Summary of Contents for QS300
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ......
Page 46: ...42 ...
Page 100: ...96 ...
Page 108: ...104 ...
Page 142: ...138 ...
Page 166: ...162 ...
Page 182: ...178 ...
Page 217: ......