190
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
In the MIDI Setup page, you can set:
•
Local control
•
Device Number
•
MIDI Transmit/Receive channels for the Voice mode
●
Local Control
Settings: off, on
This determines whether the keyboard is “connected” to the
internal tone generator of the QS300. When this is set to
on (normal condition), the Voices respond to notes played
from the keyboard of the QS300. When this is set to off,
the Voices respond only to incoming MIDI data or the
recorded data of the sequencer.
●
Device Number
Settings: off, 1 — 16, all
This determines the Device Number for the QS300, a kind
of MIDI “identification” number used to distinguish
between multiple units. For example, if you are using more
than one QS300 in a MIDI chain, set a different Device
Number for each unit.
When all is selected here, MIDI data is received over
channel 1.
Utility
MIDI Setup
Path:
u
➞
@
(MIDI)
●
Voice Mode Keyboard Transmit Channel
(TrnsCh)
Range: 1 — 16
This determines which MIDI channel the QS300 transmits
over when in the Voice mode.
●
Voice Mode Receive Channel (RcvCh)
Range: 1 — 16, omni
This determines which MIDI channel the QS300 responds
to when in the Voice mode. A setting of omni will enable
the QS300 to receive over all MIDI channels simulta-
neously.
Device
Number
Local Control
Voice Mode
Receive Channel
Voice Mode
Keyboard Transmit Channel
Summary of Contents for QS300