E
5-28
RECOIL STARTER
POWR
REMOVAL AND DISASSEMBLY
1) Remove and disassemble the recoil starter
referring to the exploded diagram. Note the fol-
lowing points.
9
Remove the start-in-gear protection device
at the recoil starter.
9
When removing the starter rope, insert a
screwdriver into the starter stop-plunger
hole to secure the sheave-drum from run-
ning off.
9
Slowly turn the sheave-drum clockwise to
spring-free, and remove the sheave-drum.
NOTE:
When removing the sheave drum, hold down the
starter spring so that the starter spring will not
spring out.
w
Wear suitable protective gloves and take care to
protect yourself from an accident due to the
spring flying out when removing the sheave
drum.
9
Holding the spring with one hand, unfold
the spring from its center with the other. Be
careful the spring does not jump out.
w
When removing or installing the starter spring,
use care not to injure your hand. It is advisable
to wear gloves.
6A9-7-5F-B1-5-b 7/25/03 10:57 AM Page 28