60H5E11
2
Item
Unit
Starter motor
Type
Output
Cranking time limit
Brushes
Standard length
Wear limit
Commutator
Standard diameter
Wear limit
Mica
Standard undercut
Wear limit
Charging system
Fuse
Lighting coil output peak
voltage
(G - G/W)
at cranking(*1)
at 1,500 r/min(*1)
at 3,500 r/min(*1)
Lighting coil resistance(*2)
(G - G/W)
Rectifier Regulator output
peak voltage
(R - B)
at 1,500 r/min(*1)
at 3,500 r/min(*1)
Charging current
Power trim and tilt system
Trim sensor
Setting resistance
Resistance
(P - B)
Fluid type
Brushes
Standard length
Wear limit
Commutator
Standard diameter
Wear limit
Hydraulic pressure (UP)
(DOWN)
kW
Second
mm (in)
mm (in)
mm (in)
mm (in)
mm (in)
mm (in)
A
V
V
V
Ω
V
V
V, A
at 6,000 r/min
Ω
Ω
mm (in)
mm (in)
mm (in)
mm (in)
MPa (kgf/cm
2
)
MPa (kgf/cm
2
)
Bendix
1.1
30
17 (0.67)
10 (0.39)
33 (1.30)
32 (1.26)
0.8 (0.031)
0.2 (0.008)
20
3
20.0
50.0
0.20 - 0.30
18
45
12, 14
9 - 11
9 - 379
ATF Dexron II
9.8 (0.386)
4.8 (0.189)
22 (0.87)
21 (0.83)
10 - 12 (100 - 120)
6 - 9 (60 - 90)
Model
200AET
L200AET
Maintenance specifications
(*1) Unloaded
(*2) The figures are for reference only.
2-6