60H5E11
Electrical systems
ELEC
Brush length limit
A
:
10.0 mm (0.39 in)
Brush continuity
Brush
1
– Brush
2
No continuity
8-19
Choke solenoid resistance:
3.4 - 4.0
Ω
4. Check the armature for continuity. Replace
if out of specification.
60h80310
Checking the brushes
1. Measure the brush length. Replace the
brush assembly if the length is shorter than
the specified limit.
60h80320
2. Check the brush holder assembly for con-
tinuity. Replace if out of specification.
60h80330
Choke solenoid
Checking the choke solenoid
1. Disengage the choke solenoid bullet con-
nector, and measure the choke solenoid re-
sistance.
60h80340
2. Connect the battery to the choke solenoid,
and check if the plunger is pulled in.
60h80350
Armature continuity:
Commutator segments
B
Continuity
Segment
B
- Armature core
C
No continuity
Segment
B
- Armature shaft
D
No continuity