60H5E11
Bracket unit
BRKT
60H71070
60H71080
Bleeding the power trim and tilt unit
NOTE:
• Make sure that the manual valve
1
is tight-
ened up.
• Fix the power trim and tilt unit in the upright
position, and check the fluid level. If it is low,
add the fluid of recommended type to the cor-
rect level.
60h71070
1. Connect the power trim and tilt motor leads
to the battery terminals, and fully retract the
trim and tilt rods.
60h71080
60h71080
7-39
PTT motor mounting bolts:
5 N • m (0.5 kgf • m, 4 ft • lb)
T
R
.
.
Recommended power trim and tilt
fluid:
ATF Dexron II
14. Install a new O-ring
5
and the PTT motor
6
. Tighten up the bolts
7
.
60h71060
NOTE:
Align the joint and armature shaft .
15. Fill the reservoir with the recommended
fluid to the specified level.
NOTE:
If the fluid is at the correct level, the fluid should
overflow out of the check hole when the cap is
removed.
16. Install the reservoir cap.
17. Perform air bleeding.
18. Check the hydraulic pressure of power trim
and tilt unit.
Rods
PTT motor leads
Battery
terminal
Green (G)
+
DOWN
Blue (L)
–
Reservoir cap:
0.7 N • m(0.07 kgf • m, 0.5 ft • lb)
T
R
.
.