16
on, interference will be detected if it is present
for 30 seconds or longer.
• When disarmed interference will give a warning
and when armed will cause a single alarm only,
i.e. the alarm will sound only once even if there
is continuous interference.
Remote controller entry enable
Turns on and off the remote controller disarm
function.
1
Press the arrow keys to select the option.
2
Press OK to confirm.
• RC Entry E On is set as factory default.
• When the remote controller entry enable is set
to off it will not be possible to disarm the
control unit when the system is fully armed
unless an entry point device is activated first.
This feature is used to ensure that the system
cannot be disarmed with a stolen remote
control without unlocking a protected door first.
• When the RC Entry E On is set, the remote
controller can arm and disarm the system as
normal without unlocking a protected door first.
Warning beep
Turns on and off the system fault warning beep.
1
Press the arrow keys to select the option.
2
Press OK to confirm.
• Warning Beep On is set as factory default.
• The warning beep is a periodic warning tone
given by the control unit to draw user attention
in the event of a system fault being active.
Device naming
Detectors can be given names and location
descriptions to help understand system events.
The devices can be named when first installing
them or by editing them afterwards, the
procedure is similar for both situations.
1
When the Enter zone NAME menu is selected
while in the /- menu, the keypad can
be used to enter text, similar to “texting” with
a mobile telephone.
The keys have the following functions:
1
1
2
ABCabc2
3
DEFdef 3
4
GHIghi4
5
JKLjkl5
6
MNOmno6
7
PQRSpqrs7
8
TUVtuv8
9
WXYZwxyz9
0
<space>0
b
/&’.*
c
Upper or lower case selection
▲
Forward space
▼
Backward space
a
Delete character and backspace
• When the
c
key is pressed the upper and
lower case characters will toggle and will be
indicated by either a upper or lower case
“NAME” in the top line of the screen.
2
When the name is complete press OK to
confirm and return to the previous or main
menu.
• The name can be erased by clearing the display
with entering backward spaces and pressing
OK.
Further PIR programming
The PIR can be set to work in 4 different
modes:
• Whether it is armed when the control unit is in
home or away armed condition.
• Whether it is omitted in home mode.
• Whether it is installed as an entry point.
• Whether an alarm is started instantly or delayed
during the entry period.
These choices presented in the learning-in and
editing procedure and a re summarised by these
codes:
B Burglar
Armed when in away or home
armed modes
O Home Omit Not active when in home armed
mode
D Home Delay Starts entry delay when in home
armed mode
E Entry
Control unit will start the entry
time when activated
I
Instant
Works with other modes and
starts an alarm instantly when
triggered in away arm entry
period. Not available with Entry
mode