background image

16

on, interference will be detected if it is present
for 30 seconds or longer.

• When disarmed interference will give a warning

and when armed will cause a single alarm only,
i.e. the alarm will sound only once even if there
is continuous interference.

Remote controller entry enable

Turns on and off the remote controller disarm

function.

1

Press the arrow keys to select the option.

2

Press OK to confirm.

• RC Entry E On is set as factory default.
• When the remote controller entry enable is set

to off it will not be possible to disarm the
control unit when the system is fully armed
unless an entry point device is activated first.
This feature is used to ensure that the system
cannot be disarmed with a stolen remote
control without unlocking a protected door first.

• When the RC Entry E On is set, the remote

controller can arm and disarm the system as
normal without unlocking a protected door first.

Warning beep

Turns on and off the system fault warning beep.

1

Press the arrow keys to select the option.

2

Press OK to confirm.

• Warning Beep On is set as factory default.
• The warning beep is a periodic warning tone

given by the control unit to draw user attention
in the event of a system fault being active.

Device naming

Detectors can be given names and location

descriptions to help understand system events.
The devices can be named when first installing
them or by editing them afterwards, the
procedure is similar for both situations.

1

When the Enter zone NAME menu is selected
while in the /- menu, the keypad can
be used to enter text, similar to “texting” with
a mobile telephone.

The keys have the following functions:

1

1

2

ABCabc2

3

DEFdef 3

4

GHIghi4

5

JKLjkl5

6

MNOmno6

7

PQRSpqrs7

8

TUVtuv8

9

WXYZwxyz9

0

<space>0

b

/&’.*

c

Upper or lower case selection

Forward space

Backward space

a

Delete character and backspace

• When the 

c

key is pressed the upper and

lower case characters will toggle and will be
indicated by either a upper or lower case
“NAME” in the top line of the screen.

2

When the name is complete press OK to
confirm and return to the previous or main
menu.

• The name can be erased by clearing the display

with entering backward spaces and pressing
OK.

Further PIR programming

The PIR can be set to work in 4 different

modes:
• Whether it is armed when the control unit is in

home or away armed condition.

• Whether it is omitted in home mode.
• Whether it is installed as an entry point.
• Whether an alarm is started instantly or delayed

during the entry period.
These choices presented in the learning-in and

editing procedure and a re summarised by these
codes:

B Burglar

Armed when in away or home
armed modes

O Home Omit Not active when in home armed

mode

D Home Delay Starts entry delay when in home

armed mode

E Entry

Control unit will start the entry
time when activated

I

Instant

Works with other modes and
starts an alarm instantly when
triggered in away arm entry
period. Not available with Entry
mode

Summary of Contents for HSA3600

Page 1: ...HSA3600 Control panel alarm system Installation Programming Operating Keep in a handy place for reference and for future maintenance Helpline 01902 635998 ...

Page 2: ...r when a battery change is required Home and away arming In addition to fully arming the system the HSA3600 also allows you to home arm The home mode allows you to arm the system in such a way that you can protect the non sleeping areas such as downstairs allowing access from the bedroom to the bathroom for example without triggering the alarm Take care of your safety Display extreme caution when ...

Page 3: ...ton contents Control unit External siren 2 x PIRs 2 x door contacts 2 x door contact magnets 4 x 1 5V AAA alkaline cells 6 x 1 5V AA alkaline cells 8 x 1 5V D alkaline cells 2 x large adhesive pads 2 x small adhesive pads 4 x small wall plugs 12 x medium wall plugs 4 x large wall plugs 4 x 4mm x 30mm cross head fixing screws 4 x 3 5mm x 22mm cross head fixing screws 12 x 3 5mm x 16mm cross head fi...

Page 4: ...ot be mounted on or near large metal objects Avoid obvious sources of electrical interference such as fridges and microwave ovens Tamper switches When mounting devices ensure that any tamper switches close fully On uneven surfaces it may be necessary to place packing behind the switch for reliable operation Extend the system Extend the system in the future to increase your security or as your need...

Page 5: ...ires or boilers and do not position directly above radiators Avoid mounting the PIR directly facing a window Do not point the PIR at a door protected by a door window contact Keyfob remote control accessory Can be used inside or outside the property and can be kept on your keyring Door Window contact Select a door that will be the main point of entry and exit usually your front door Mount as high ...

Page 6: ...h the four screws taking care not to over tighten WARNING The siren is very loud avoid touching the tamper switch arm or opening and closing the lid unnecessarily 6 OK 5jkl 6mno 7pqrs 8tuv 9wxyz 0 1 2abc 3def 4ghi Unpack all the parts onto a table top Identify all the parts to get to know the system and get up and running quickly by programming them on a table top before installing them 2 Siren WA...

Page 7: ...PP3 battery as shown The Tx LED will flash briefly while components initialise Smoke detector accessory Twist off backing plate and insert 4 AAA batteries as shown Remote keyfob accessory Slide off the battery cover insert the 23A MN21 battery as shown and replace cover Switch to on Tamper switch Jumper switch Learn Test button Tamper switch Jumper switch Extension terminals Magnet Learn Test butt...

Page 8: ...efore you can deactivate the alarm or enter any information you must enter PIN code This is factory set to 0000 Disarm 1 Key in 0 if not already lit the display will light up and Enter Code is displayed 2 Key in 000 to complete the factory set code 3 Press OK you will hear 2 short beeps and the display will show Alarm Off The system is now disarmed If no code is entered for a while the display wil...

Page 9: ...ke care not to activate the siren tamper switch unnecessarily The siren is programmed by the jumper switches in the left hand compartment 1 Lift off jumper 1 and park it The siren will beep and flash The siren is now in learn mode 2 Lift off jumper 5 and park it This must be left in the off position permanently If jumper 3 and jumper 4 are removed during the learning in process the siren will only...

Page 10: ...sting Ensure they are replaced in your chosen positions before replacing the covers 7 Replace the battery and compartment covers ensuring that the gasket between the electronics compartment and cover is correctly located and the wires placed in their slots to ensure a good seal from the environment 8 Enable the tamper switch by selecting Program Siren menu on the control unit then Siren A T On and...

Page 11: ... or flaky paint or on a rough surface Screw mounting Remove the front of the device and if necessary break through the appropriate knockout where the plastic is thinner Using the holes as a template drill holes in the surface and insert the wall plugs if fixing into the plaster or brick Control unit Open the control unit and using the 4 holes as shown fix the control unit to a wall as described un...

Page 12: ...n condition is detected 4 Remove the detector put the jumper in the normal off position Screw the detector back onto its base When the jumper is in the normal off position the indicator light will normally be off It will only light if there is a problem either a low battery or a tamper condition Ensure that the jumper is in the normal off position when testing is finished otherwise low battery and...

Page 13: ...tivate the alarm immediately while if a Home Omit sensor is triggered the control unit will not respond if in home mode If a 24 hour alarm fire alarm personal attack alarm tamper or auxiliary alarm is triggered the control unit will activate the alarm immediately irrespective of what alarm mode the control unit is in During an alarm the control unit will sound the siren depending on the programmed...

Page 14: ...led up and down and viewed with the keys the most recent event will be at the start Dual key alarm feature Personal emergency alarm A personal emergency alarm can be triggered at the control unit by pressing keys 1 and 3 simultaneously for 2 seconds Fire alarm A fire alarm can be triggered in a similar way by pressing keys 4 and 6 simultaneously for 2 seconds System records For your future conveni...

Page 15: ... alter the entry delay time Options are 0 sec 10 sec up to 70 sec in 10 second increments 1 Use the arrow keys to switch between options 2 Press OK to confirm 10 seconds is set as factory default Exit time Enables you to alter the exit delay time Options are 0 sec 10 sec up to 70 sec in 10 second increments 1 Use the arrow keys to switch between options 2 Press OK to confirm 10 seconds is set as f...

Page 16: ...em or by editing them afterwards the procedure is similar for both situations 1 When the Enter zone NAME menu is selected while in the Device menu the keypad can be used to enter text similar to texting with a mobile telephone The keys have the following functions 1 1 2 ABCabc2 3 DEFdef 3 4 GHIghi4 5 JKLjkl5 6 MNOmno6 7 PQRSpqrs7 8 TUVtuv8 9 WXYZwxyz9 0 space 0 b c Upper or lower case selection Fo...

Page 17: ...n The light does not flash normally when it is sensing movement unless the jumper is in the On test position If the LED flashes it indicates that it has either been tampered with or the battery is getting low and needs replacing Further door contact programming The door contact can be set to work in 6 different modes Whether it is armed when the control unit is in home or away armed condition Whet...

Page 18: ...help button and a smoke alarm These are available separately from your local stockist Testing the system Testing the system should be done on a regular basis and after any alterations PIR sleep feature The PIR has a built in sleep timer to save battery power If there is no movement in front of the PIR for 1 minute the PIR will become ready to signal and any movement will be reported The PIR will s...

Page 19: ... complete Using To activate press and hold the red button for at least 2 seconds LED will light momentarily and the alarm will be activated To silence an alarm press and hold down the red button after 10 seconds the LED will light momentarily for a second time alarm will be silenced Please note that silencing the alarm with the help button does not reset the system If the alarm is armed prior to a...

Page 20: ...ere all the zones with the sensor types and names are listed 1 Use the arrow keys to move the cursor to the position where the device listed is to be deleted The list is displayed in zone number order 2 Press OK The selected device will be displayed to confirm Press a to exit if you do not want to delete this device the screen will return to the previous list 3 Press OK to delete Editing a device ...

Page 21: ...b The LED will either be very dim or will not light at all when the battery is low Change the battery as soon as possible with an alkaline replacement Keypad The Tx will flash repeatedly every time the device is used indicating a low battery and the control unit will identify the keypad with a low battery Before changing the battery check that the tamper switch is operating correctly 1 Disable tam...

Page 22: ...th flying near the PIR can trigger an alarm PIR LED flashes when the jumper is in the normal position Batteries are low or the tamper switch is disturbed Check that the tamper spring is making contact with the base If the tamper switch is OK change batteries with new alkaline replacements PIR does not respond to movement when jumper is in test position Batteries are completely exhausted Change bat...

Page 23: ...ontrolled dual edge sequential pulse count with pulse length discrimination Radio 433 92Mhz AM transmitter Power supply 4 5V 3 X AA alkaline cells 3 years minimum typical domestic service life Door contact Radio Microprocessor controlled 433 92Mhz AM transmitter Power supply 3V 2 X AAA alkaline cells 3 years minimum typical domestic service life 50 activations per day Smoke detector Detector Micro...

Page 24: ...ds WV13 1LA Yale is a registered trademark E2 11 03 Key points Stopping the alarm Key in your PIN code and press OK on the control panel If any of the devices beep or flash they have either been tampered with See trouble shooting page 22 or require a new battery See how to change a battery page 20 ...

Reviews: