Troubleshooting
2. A message similar to the following one appears for approximately 10 seconds after the self
tests complete.
Terminal Server, Type 74, Rev x.xx.x
Ethernet address 08-00-87-xx-xx-xx, port x
Initializing...
3. A message similar to the following one is displayed while the server is waiting for a response to the
load request. If this message does not appear after you type several <RETURN>s, the MAXserver
1600 could be at fault. Call Xyplex Customer Support. (In the U.S., call 1-800-435-7997. For
International calls, the number is 508-264-9903).
Terminal Server, Type 74, Rev x.xx.x
Ethernet address 08-00-87-xx-xx-xx, port x
Requesting network load service
If the this message remains displayed for more than 20 seconds after you type several <RETURN>s,
either the MAXserver 1600 is not configured on a load server, or it cannot communicate with a load
server. Check that the MAXserver 1600 is in the RUN state and that the Ethernet transceiver cable or
ThinWire network cable is properly installed.
4. A message similar to the following one is displayed if the MAXserver 1600 has received a load offer
from a
load server:
Terminal Server, Type 74, Rev x.xx.x
Ethernet address 08-00-87-xx-xx-xx, port x
Evaluating service offers
If you typed a <CTRL><T> after "autobauding" your terminal, messages similar to these will appear
when the unit has stopped accepting load offers:
Received load service offers:
Host Address protocol merit filename
xx-xx-xx-xx-xx-xx 0809 9C000037 MX1500
One to ten load server addresses are displayed (typically, just one). The MAXserver 1600 selects
the load server with the highest merit value.
0590