Chapter 3
Troubleshooting
3.1
Overview
Refer to this chapter if you experience a problem with your MAXserver 1600 or 1608. This chapter describes:
•
How to troubleshoot startup and loading problems
•
What to do if the LAN light on the front panel goes out
•
How to reset the MAXserver 1600/1608
3.2
Startup/Loading Problems
Refer to this section if you have powered up the MAXserver 1600, or re-initialized the unit, and the front panel
lights do not behave as follows after several minutes. (Procedures for the MAXserver 1608 are identical.)
•
RUN light flashes slowly
•
LAN light flashes as Ethernet packets are received
Normally, the light pattern appears as follows when you power up the MAXserver 1600, or re-initialize the
unit:
1. All lights ON for approximately one second.
(The MAXserver 1600 is testing the lights.)
2. Each port light goes ON in order -- 16 to 1.
(The MAXserver 1600 is running a self test.)
3. The RUN light flashes rapidly.
(The self test has completed.)
4. The LAN light goes ON.
(The MAXserver 1600 is starting the software loading process.)