The recalibration requires a data exchange between the sensor and the web browser. If
performed by remote, the connection bandwidth will impact the duration and can take
several minutes. In such case we suggest a connection with at least 200kbytes/s.
When the re-calibration is done, it is applying to the sensors
by clicking on “Next”.
3.2.7.8
Validate the person size
In the succeeding screen, the user is asked to verify the person size. This is important to
validate the distance measurement of the sensor. In most cases, especially on mounting
heights below 3.5 meters, the person sizes will be quite exact without an additional
correction (precision is better than +/- 10 cm). But in several situations, the sensor might not
be able to correctly measure the scene and therefore measures the person sizes incorrectly.
If the average person size or the sizes printed on the bubbles within the scene seem to be
unrealistic, a correction can be applied. For this, the toggle switch in the “Correct person
172 cm