![Xinje DS2 series User Manual Download Page 20](http://html.mh-extra.com/html/xinje/ds2-series/ds2-series_user-manual_887459020.webp)
12
DS2-43P0-AS/AS6
Terminal
Function
Explanation
R/S/T
Power supply input of
main circuit
3 phase AC 360
~
400V, 50/60Hz
●
Vacant
U
、
V
、
W
Motor terminals
Connect the motor
Terminal
Color
U
brown
V
black
W
blue
PE
Yellow green
P+
、
D
、
C Internal
regenerative
resistor
Short P+ and D, disconnect P+ and C,
set P0-10=0
External
regenerative
resistor
Connect regenerative resistor between
P+ and C, disconnect P+ and D, set
P0-10=1
P+/P-
Bus terminal
Real-time check the bus voltage, please
take attention of this terminal
DS2-20P4-BS/BS6
Terminal
Function
Explanation
L/N
Power supply input of
main circuit
Single phase AC 200
~
240V, 50/60Hz
●
Vacant
U
、
V
、
W
Motor terminals
Connect the motor
Terminal
Color
U
brown
V
black
W
blue
PE
Yellow green
P+/PB
External
regenerative
resistor
Connect regenerative resistor between
P+ and PB
P+/P-
Bus terminal
Real-time check the bus voltage, please
take attention of this terminal
R
S
T
.
U
V
W
P+
D
C
P-
.
.
.