![Xinje DS2 series User Manual Download Page 19](http://html.mh-extra.com/html/xinje/ds2-series/ds2-series_user-manual_887459019.webp)
11
3-1-2. Main circuit terminals
DS2-20P2-AS/AS6, DS2-20P4-AS/AS6, DS2-20P7-AS/AS6
Terminal Function
Explanation
L1/L2/L3
Power supply input of
main circuit
Single or 3 phase AC 200
~
240V, 50/60Hz
Ground
Connect to ground terminal of motor then
connect to the ground
P+
、
PB
Regenerative resistor
Connect regenerative resistor between P+
and PB
U
、
V
、
W Motor terminals
Connect the motor
Terminal
Color
U
brown
V
black
W
blue
PE
Yellow green
Ground
Connect to ground terminal of motor then
connect to the ground
DS2-21P5-AS/AS6/AS2, DS2-22P3-AS/AS6, DS2-41P5-AS/AS6
Terminal
Function
Explanation
R/S/T
Power supply input of
main circuit
3 phase AC 200
~
240V, 50/60Hz
(DS2-2□P□-AS)
R/S/T
Power supply input of
main circuit
3 phase AC 360
~
400V, 50/60Hz
(DS2-4□P□-AS)
●
Vacant
U
、
V
、
W
Motor terminals
Connect the motor
Terminal
Color
U
brown
V
black
W
blue
PE
Yellow green
P+
、
D
、
C Internal
regenerative
resistor
Short P+ and D, disconnect P+ and C,
set P0-10=0
External
regenerative
resistor
Connect regenerative resistor between
P+ and C, disconnect P+ and D, set
P0-10=1
Ground
Connect to ground terminal of motor,
then connect to the ground
R
S
T
.
U
V
W
P+
D
C