General Troubleshooting
4-53
Drum Maint/Transfix Home
This test drives the process motor a short distance in each direction to verify that the dmfix drive
unit was in its home position.
R#
Definition
Typical
Value
Actions
0
DM Initial FE Peak
(pm motor counts)
MFG
Only
Reports the height of the initial peak when
starting rotation of the dm drive gear.
1
DM Initial FE Peak
Time (sec)
MFG
Only
Reports the time since the start of CCW
motion until the peak was detected.
2
TF Initial FE Peak
(pm motor counts)
MFG
Only
Reports the height of the initial peak when
starting rotation of the tf drive gear.
3
TF Initial FE Peak
Time (sec)
MFG
Only
Reports the time since the start of CW motion
until the peak was detected.