Scanner Platen Steps
1.
Place the Scanner Calibration page on the platen with the top edge to the left as
shown.
Note
Make sure the calibration page is aligned correctly. If the page is misaligned,
the calibration procedure fails.
2.
Close the document feeder.
3.
In the menu, select
Document Glass Step
, and then press the Enter button to
scan the calibration page.
4.
When the scan completes, check the control panel message:
■
If the control panel indicates
Success
, select
Continue
, press the Enter
button, and then continue with Step 5.
■
If the control panel indicates
Failure
, select
Continue
, press the Enter
button, and then repeat Steps 1–4.
5.
Remove the Scanner Calibration page from the platen.
6.
Continue with the Document Feeder Steps on page 6-11.