37,022.40:
PEST - Pressure pump motor disconnect. The pressure pump motor is
not drawing the expected power from the supply.
37,023.41:
PEST - Purge valve disconnect. The purge valve is not drawing the
expected power from the supply.
37,024.42:
PEST - Drum heater relay board disconnect. Both drum heater relay coils
are not drawing the expected power from the supply.
37,025.43:
PEST - Drum heater relay A disconnect. The drum heater A coil is not
drawing the expected power from the supply.
37,026.44:
PEST - Drum heater relay B disconnect. The drum heater B coil is not
drawing the expected power from the supply.
Troubleshooting Procedure
Step
Questions and Actions
Yes
No
1
1.
Run the Pressure Pump Motor test.
2.
Did the test pass?
Replace the
electronics
module.
Go to Step 2.
2
1.
Check the purge pump assembly wiring.
2.
Is the wiring damaged?
Replace the pressure pump motor.
Troubleshooting Procedure
Step
Questions and Actions
Yes
No
1
1.
Run the Purge Vent Solenoid test.
2.
Did the test pass?
Go to Step 2.
Replace the
purge pump.
2
1.
Check the purge pump assembly wiring.
2.
Is the wiring damaged?
Replace the defective wiring or the
purge pump.
Troubleshooting Procedures
Step
Questions and Actions
Yes
No
1
1.
Run the Drum Heater Relay test.
2.
Did the test pass?
Replace the
electronics
module.
Go to Step 2.
2
1.
Check the wiring for damage.
Replace the drum heater relay
board.
Summary of Contents for WORKCENTRE C2424
Page 1: ...WorkCentre C2424 copier printer Service Manual ...
Page 2: ......
Page 16: ...xii WorkCentre C2424 Copier Printer ...
Page 24: ...xx WorkCentre C2424 Copier Printer ...
Page 92: ...2 48 WorkCentre C2424 Service Manual ...
Page 300: ...6 14 WorkCentre C2424 Service Manual ...
Page 374: ...8 64 WorkCentre C2424 Service Manual s2424 214 Back Frame ...
Page 431: ......
Page 432: ...604E13990 ...