Wiring
Phaser 6600 and WorkCentre 6605
Xerox Internal Use Only
Service Manual
7-32
Fuser
Signal line name
Description
HEAT2
HEAT1
HEAT EN
Temperature control signal of the Fusing Assembly
FUSE CUT
Control signal of the Fuse
FSR TEMP VD
FSR TEMP VC
Temperature data measured by the Center Temp. Sensor
FSR STS
Temperature data measured by the Rear Temp. Sensor
MCU Board
PL18.1.13
LVPS
PL18.1.34
Fuser Assembly
PL7.1.1
P/J47
1
3
2
P/J29
1
2
3
5
4
P/J28
1
2
P/J508
5
4
3
2
1
FUSER RLY
Heater
Control
6
7
4
3
5
P/J281
7
6
2
5
1
4
3
+5VDC
P/J281
1
2
HEAT EN
RTN
HEAT2
HEAT1
FUSE CUT
SG
SG
LINE
HEART
P/J177
2
Fuse
1
1
2
J176
2
1
FSR STS
Rear Temperature
Sensor
J175
3
1
2
3
2
1
Center Temperature
Sensor
FSR TEMP VD
FSR TEMP VC
+5VDC
From
AC Power
SG
N.C.
Top Harness Assembly
PL18.2.5
Heater Harness Assembly
PL7.1.5
Top Harness Assembly
PL18.2.5
s6600-221
Summary of Contents for WorkCentre 6605
Page 2: ......
Page 4: ...Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual ii ...
Page 352: ...Image Quality Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 3 26 ...
Page 568: ...Parts Lists Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 5 64 ...
Page 644: ...Wiring Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 7 52 ...
Page 654: ...Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual A 10 ...
Page 660: ...Index Phaser 6600 and WorkCentre 6605 Service Manual I 6 ...
Page 661: ......