Service Parts Disassembly
Xerox Internal Use Only
Phaser 6600 and WorkCentre 6605
Service Manual
4-69
Roller Kit Assembly
(PL13.2.98)
1.
Remove the Bypass Tray Frame Assembly (page 4-65).
2.
Remove the Feed Spring (PL13.2.7).
3.
Release the hook holding the Bypass Tray Feed Gear (PL13.2.8) and remove the gear from the
Bypass Tray Feed Shaft (PL13.2.14).
4.
Release the hook holding the Left Bypass Tray Cam (PL13.2.11), and slide the cam to the right.
5.
Slide the Roller Kit Assembly (PL13.2.98) to the left to release the right end of the shaft, and then
swing the right end of the shaft toward the front while shifting the shaft to the right in order to
free the left end.
Replacement Note:
Make sure that the solenoid actuator is below the shaft when reinstalling the
Roller Kit Assembly.
s6600-131
Front
Solenoid Actuator
L Bypass Tray Cam