Service Parts Disassembly
Xerox Internal Use Only
Phaser 6600 and WorkCentre 6605
Service Manual
4-77
Duplex
Duplex Assembly
PL14.1.1
WARNING:
The Fuser is very hot. Take added care when handling the fuser to avoid being burned.
1.
Open the Rear Door Assembly (PL19.1.95).
2.
Remove the Transfer Roller. (page 4-79)
3.
Remove the screw (silver, tapping, 8mm) that attaches the power supply (pink wire) to the Duplex
Assembly (PL14.1.1), and release the wire from the harness guide.
4.
Remove the Rear Cover Links by raising the Rear Cover slightly so that the holes on the Rear Cover
Links can be released from the keyed bosses on the left and right.
5.
Raise the steel hinge pin on the left side and slide the pin to the right to remove it.
6.
Swing the right side of the assembly out so that the corner is clear of the frame, then move the
assembly to the left to disengage the hinge pin on the right side. When the grounding spring is
clear of the hinge pin, lift the Rear Cover/Duplex Assembly away from the printer.
s6600-183
Rear
Summary of Contents for WorkCentre 6605
Page 2: ......
Page 4: ...Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual ii ...
Page 352: ...Image Quality Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 3 26 ...
Page 568: ...Parts Lists Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 5 64 ...
Page 644: ...Wiring Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual 7 52 ...
Page 654: ...Phaser 6600 and WorkCentre 6605 Xerox Internal Use Only Service Manual A 10 ...
Page 660: ...Index Phaser 6600 and WorkCentre 6605 Service Manual I 6 ...
Page 661: ......