General Information
Phaser 6600 and WorkCentre 6605
Xerox Internal Use Only
Service Manual
1-46
Exit
The Exit Sensor (PL17.1.11) detects when media is present in the fuser.
The Full Stack Sensor (PL17.1.11) detects when the output tray is full.
The Exit Drive Assembly (PL17.1.21) consists of the following components.
•
Exit Clutch 1 — Transfers the drive of the Main Motor to the Exit Roller. The Exit Roller rotates in
the paper exit direction.
•
Exit Clutch 2 — Transfers the drive of the Main Motor to the Exit Roller. The Exit Roller rotates in
the duplex feed direction.
s6600-256
Exit Sensor
Full Stack Sensor
Exit Clutch 1
Exit Clutch 2
Exit Drive Assembly