8 Printer Environment Settings
262
NOTE:
Use the DHCP server together with the Windows Internet Name Server
(WINS) server.
If you selected [STATIC] in step 5, then proceed to step 6 to configure the protocol
settings. Otherwise, proceed to step 12.
6.
Select [IPv4 - IP Address], and then [Change Settings].
7.
Use the keypad on the screen to enter an IP address for the machine in the format
“xxx.xxx.xxx.xxx”. When you have finished entering all values, select [Save].
8.
Select [IPv4 – Subnet Mask], and then [Change Settings].
9.
Using the same method as in step 7, enter a subnet mask.
10.
Select [IPv4 – Gateway Address], and then [Change Settings].
11.
Using the same method as in step 7, enter a gateway address.
NOTE:
If you do not wish to set the gateway address, leave this field blank.
12.
Select [IPv4 – IP Filter], and then [Change Settings].
13.
Select [Enabled] to filter access to the machine.
NOTE:
If you do not wish to use the IP filter feature, select [Disabled].
NOTE:
Use CentreWare Internet Services to register the IP addresses which are not
allowed to access the machine. Refer to
CentreWare Internet Services on page 149
.
14.
When you have finished establishing TCP/IP, select [Close] on the [Protocol
Settings] screen.
When [IPv6 Mode] or [Dual Stack] is selected in step 3
4.
Set [IPv6 Address Manual Configuration].
NOTE:
Select [Enabled] when the machine is connected to a network on which IPv6
stateless address autoconfiguration is disabled, or when you want to set a static IPv6
address.
If you selected [Enabled] in step 4, proceed to step 5. Otherwise, proceed to step 11.
5.
Select [Manually Configured IPv6 Address], and then [Change Settings].
6.
Use the keypad on the screen to enter an IP address for the machine in the format
“xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx”. Select [Save].
7.
Select [Manually Configured IPv6 Prefix], and then [Change Settings].
8.
Enter an IP address prefix, and then select [Save].
9.
Select [Manually Configured IPv6 Gateway], and then [Change Settings].
10.
Using the same method as in step 6, enter a gateway address.
11.
Select [IPv6 – IP Filter], and then select [Enabled] or [Disabled].
NOTE:
If you do not wish to use the IP filter feature, select [Disabled].
NOTE:
Use CentreWare Internet Services to register the IP addresses which are not
allowed to access the machine. Refer to
CentreWare Internet Services on page 149
.
12.
When you have finished establishing TCP/IP, select [Close] on the [Protocol
Settings] screen.
Summary of Contents for WorkCentre 5222
Page 1: ...User Guide ME3612E4 1 System Administration Guide XE3022EN0 2 ...
Page 12: ...12 ...
Page 28: ...2 Paper and Other Media 28 ...
Page 62: ...5 Machine Status 62 ...
Page 148: ...6 Setups 148 ...
Page 232: ...7 CentreWare Internet Services 232 ...
Page 274: ...8 Printer Environment Settings 274 ...
Page 282: ...9 E mail Environment Settings 282 ...
Page 430: ...15 Problem Solving 430 ...
Page 444: ...16 Appendix 444 ...