REP 2.14 Nudger Pawl and
Nudger Pawl Spring
Parts List on PL 2.2
Removal
1. Remove power cord.
2. Remove document catch tray assembly
(REP 1.1).
3. Remove RH cover (REP 1.2).
4. Remove coupler cover (REP 1.3).
5. Remove LH cover (REP 1.4).
6. If installed, remove A8 store & forward
PWB (REP 5.4).
7. Remove A2 main PWB (REP 5.5).
8. Remove power supply assembly (REP 5.6).
9. Remove CNC PWB assembly (REP 5.10).
10. Remove nudger solenoid assembly (REP
2.13).
11.Remove nudger pawl and nudger pawl
spring. (Figure 1)
a.
Rotate nudger pawl away from
nudger clutch.
b.
Remove nudger pawl spring from LH
frame.
c.
Remove nudger pawl and nudger
pawl spring.
Replacement
1. Reinstall in reverse order.
2. Check that spring is positioned in the
detent on the locating tab on the LH
frame.
REP 3.1 Scan Position Sensor
Parts List on PL 3.1
Removal
1. Remove power cord.
2. Remove document catch tray assembly
(REP 1.1).
3. Remove control panel assembly (REP 5.1).
4. Remove upper scan cover (REP 1.7).
5. Remove scan position sensor.
a.
Remove scan sensor bracket from
scan input idler roller.
b.
Remove scan position sensor from
scan sensor bracket.
c.
Disconnect J405 at scan position
sensor.
Continued