A10 Setup for USO, XCI and RX
The configuration switch(es) on the A10
Autodialer/Data Coupler PWB control(s) how
the terminal will respond to the customer’s
specific telephone equipment.
USO:
1. No specific requirements (see Note,
Table 1).
XCI:
1. No specific requirements (see Note,
Table 1).
RX:
1.
Position Shorting Links.
a. Certain links depend upon local
installation conditions. Refer to Table 2,
for explanation. Move shorting links on
the A10 Coupler PWB. Refer to Figure
1.
2.
Connect data cable to the A10 Coupler
PWB and telephone network. Refer to
Figure 1.
3.
To set transmission level, refer to Tables
2, 2A, 4, and 4A.
RX: Service (PSR) Mode
The A10 Coupler PWB incorporates Coupler
Switch SW 1. This switch contains the
following bit switches (see Figure 1):
•
A10 SW 1 Bit 1 - Conf. 1 (Table 3A).
•
A10 SW 1 Bit 2 - Conf. 0 (Table 3A).
•
A10 SW 1 Bit 3 Remote Diagnostics (Table
3B).
•
A10 SW 1 Bit 4 Service (PSR) Mode (Table
3B).
1.
To Enable Service Mode:
a. Remove power cord.
b. Remove the coupler cover.
c. Position A10 SW 1 bit 4 to the ”ON”
position.
d. Reinstall power cord.
e. Top line of display blinks to indicate
terminal is in service mode.
2.
To Disable Service (PSR) Mode:
a. Remove power cord.
b. Position A10 SW 1 bit 4 to the ”OFF”
position.
c. Reinstall the coupler cover.
d. Reinstall power cord.
e. Top line of display remains steady
indicating Service (PSR) Mode is
disabled.
RX: Remote Diagnostic Mode
The A10 Coupler PWB incorporates Coupler
Switch SW 1. This switch contains the
following bit switches (see Figure 1):
•
A10 SW 1 Bit 1 - Conf. 1 (Table 3A).
•
A10 SW 1 Bit 2 - Conf. 0 (Table 3A).
•
A10 SW 1 Bit 3 Remote Diagnostics (Table
3B).
•
A10 SW 1 Bit 4 Service (PSR) Mode (Table
3B).
1.
To Enable Remote Diagnostic Mode:
a. Remove power cord.
b. Remove the coupler cover.
c. Position A10 SW 1 bit 3 to the “ON“
position.
d. Reinstall the coupler cover.
e. Reinstall power cord.
f. Select Menu 53. Display indicates:
53
REMOTE DIAGNOSTICS
PRESS (ENTER) OR (SCROLL)
2.
To Disable Remote Diagnostics Mode:
a. Remove power cord.
b. Remove the coupler cover.
c. Position A10 SW 1 bit 3 to the ”OFF“
position.
d. Reinstall the coupler cover.
e. Reinstall power cord.
f. Select Menu 53. Display indicates:
53
NOT AVAILABLE
12/88
Telecopier 7017 / 7017SF
6-13
Installation
www.printcopy.info
www.printcopy.info