Table 26
System Data: 41
NOTE 1:
USO: When Bit 4 = 0, dial tones above -25 dBm are valid; dial tones below -25 dBm are invalid.
RX only: When Bit 4 = 0, ATT2 is disabled. Telephone Network tone detection level defaults to -51 dBm. (This does not affect
facsimile data receive level.) Signal level detect can be adjusted in accordance with Table 4A under Installation in this Service
Manual.
NOTE 2:
When Bit 5 = 0, breaks of >2 seconds in line current will be detected after going on line.
NOTE 3:
Bit 6=0, Bit 7=0 Not Detect:
The auto dialer will not look for dial tone at all. Initially the autodialer will wait for the time specified
in system data byte 43 and then dial. When a pause is inserted in the digit train the autodialer will
wait for the time set in system data byte 42 and then continue dialing.
Bit 6=1, Bit 7=0 Not Detect:
Same as Bit 6=0,Bit 7=0
Bit 6=0, Bit 7=1 Not Detect Initial:
The autodialer will not look for the first dial tone (for example, ignore PBX dial tone), it will
wait for the time set up in system data byte 43 and then start dialing. When a pause is
inserted, the autodialer will go to detect dial tone.
Bit 6=1, Bit 7=1 Detect: The autodialer will look for the first dial tone and will also look for dial tone when a pause is inserted.
System Data
Description
Redial
Dialing
Dialing Rate
Dial tone detect
(See Note 3)
Line current
Dial tone signal level
Manual dial
Bit No.
Bit Definition
0
1
7
0
1
2
3
4
5
6
Default
USO
RX
0
0
0
1
0
1
1
1
1
1
1
0
1
0
0
0
Redial
Pulse dialing
Does not redial
DTMF dialing
20 pps
10 pps
Disable
Signal level not detect
Enable
Signal level detect
(Note 1)
Not detect
Detect (Note 2)
0
1
0 Not
1
: Not
: Not
:Detect
:Detect
0 Detect
0 Detect
1 Initial 1
12/88
System Data Setup
6-37
Telecopier 7017 / 7017SF
www.printcopy.info