8-12
Phaser 6180MFP Multifunction Printer Service Manual
Service Parts Disassembly
Fuser Unit (PL6.1.10)
Warning
The Fuser may be hot. Turn the printer power Off and allow at least 5
minutes for the Fuser to cool before removing the Fuser.
1.
Open the Front Cover.
2.
Open the Duplex Gate Chute (PL6.1.13).
3.
Release the levers on the left and right sides of the Fuser to unlock the
Fuser from the printer.
4.
Lift the green latches, push the Fuser toward the front, and lift the Fuser
up to remove it.
s6180mfp-129
Duplex Gate Chute
Summary of Contents for Phaser 6180MFP
Page 1: ...Service Manual Phaser 6180MFP 701P47020 Multifunction Printer ...
Page 2: ......
Page 20: ...xviii Phaser 6180MFP Multifunction Printer Service Manual ...
Page 32: ...xxx Phaser 6180MFP Multifunction Printer Service Manual ...
Page 82: ...1 50 Phaser 6180MFP Multifunction Printer Service Manual General Information ...
Page 188: ...2 106 Phaser 6180MFP Multifunction Printer Service Manual Theory of Operation ...
Page 412: ...3 224 Phaser 6180MFP Multifunction Printer Service Manual Error Messages and Codes ...
Page 526: ...4 114 Phaser 6180MFP Multifunction Printer Service Manual General Troubleshooting ...
Page 596: ...5 70 Phaser 6180MFP Multifunction Printer Service Manual Print Quality Troubleshooting ...
Page 618: ...7 8 Phaser 6180MFP Multifunction Printer Service Manual Cleaning and Maintenance ...
Page 748: ...8 130 Phaser 6180MFP Multifunction Printer Service Manual Service Parts Disassembly ...
Page 798: ...9 50 Phaser 6180MFP Multifunction Printer Service Manual Parts List ...
Page 870: ...A 18 Phaser 6180MFP Multifunction Printer Service Manual Reference ...
Page 882: ...I 12 Phaser 6180MFP Multifunction Printer Service Manual Index ...
Page 883: ......
Page 884: ...701P47020 ...