6-50
Phaser 6115MFP Multifunction Product Service Manual
Adjustments and Print Function Settings
Additional ADF Adjustment Procedures
ADF FD Magnify
Adjusts the scanning zoom ratio in the FD (feed) direction of the Auto
Document Feeder Unit.
When to Use:
■
When a new Auto Document Feeder Unit is mounted.
Specification:
■
200 mm ± 1.4 mm
Adjustment Range:
■
The default setting is 0%.
■
Adjustment Range: -5% ~ +5%
Procedure:
1.
Prepare a test chart (A4 or 11 x 8 1/2) as shown below:
■
Draw a 200-mm-long straight line A, starting with a point 20 mm from
the left edge and 105 mm from the top edge
2.
Enter the SERVICE MODE.
3.
Select [ADF FD MAGNIFY] of [1 ADJUST] and press the Menu/Select
key.
4.
Load the test chart in the ADF and press the Start key.
5.
Measure the length of line A on the copy to check that it falls within the
specified range.
s
6115-361
A
20 mm
105 mm
200 mm