6-48
Phaser 6115MFP Multifunction Product Service Manual
Adjustments and Print Function Settings
Scanner FD Registration
Adjusts for variations in machining and installation accuracy of different
Scanner parts. The adjustment varies the scanning zoom ratio in the sub
scanning direction.
When to Use:
■
When the original glass is replaced.
■
When the scanner unit is with a new one.
Specification:
■
20mm +/- 1.0mm
Adjustment Range:
■
The default setting is 0.00.
■
Adjustment range: -5.00 (-5.00 mm) ~ “0.00 (0.00 mm)” ~ +5.00 (+5.00
mm).
Procedure:
1.
Complete “PRN Sub Regist” on page 6-11.
2.
Prepare a chart (A4S or 11 x 8 1/2S) by drawing a reference line on a
sheet of paper at a position 20 mm away from the edge as illustrated
below.
3.
Enter the Service mode.
4.
Select [SCANNER FD REGIST] of [1 ADJUST] and press the Menu/
Select key.
5.
Place the chart on the original glass and press the Start key.
6.
Measure dimension B on the copy produced to check to see if it falls
within the specified range.
7.
Press the Menu/Select key, adjust using the +/- key, and then press the
Menu/Select key to validate the setting.
8.
Repeat steps 5 to 7 until the measurement of dimension A falls within the
specified range.
s
6115-362
Width A: 20 mm
Summary of Contents for Phaser 6115 MFP
Page 1: ...Service Manual Phaser 6115MFP 701P28980 Color Laser Multifunction Product...
Page 2: ......
Page 44: ...1 22 Phaser 6115MFP Multifunction Product Service Manual General Information...
Page 144: ...3 42 Phaser 6115MFP Multifunction Product Service Manual Error Codes and Messages...
Page 270: ...7 16 Phaser 6115MFP Multifunction Product Service Manual Cleaning and Maintenance...
Page 530: ......
Page 531: ......
Page 532: ...701P28980...