Troubleshooting
Phaser 3330 and WorkCentre 3335/3345
Xerox Internal Use Only
Service Manual
2-68
Over Heat Error
The Fuser exceeded the temperature set point.
Applicable Error
•
10-300: Over Heat error
Initial Actions
•
Check the Fuser and Fan vents for debris.
•
Turn the Machine off and then on again.
•
If the problem persists continue troubleshooting.
Troubleshooting Reference Table
WARNING:
Do not touch the fuser while it is hot.
Troubleshooting Procedure Table
Applicable Parts
Wiring and Plug/Jack Map Reference
• Thermistor, (PL 3.3.2,
• Fuser, (PL 3.3.36,
• Phaser 3330 Main PWB Connector Designators
• Phaser 3330 Control Panel PWB
• Wiring Diagrams for P3330/WC3335/WC3345
• WorkCentre 3335/3345 Main PWB Connector Designators
• DADF PWB
• SMPS PWB
Step
Actions and Questions
Yes
No
1.
Remove then reinstall Fuser.
Does the error persist?
Go to step 2.
Complete.
2.
• If the problem persists, turn the machine
off and remove the Fuser (PL 3.3.36,
• Check if the Fuser connector is
connected properly (CN 3).
• Check if the input voltage is normal.
• Check if the Thermistor is twisted or
contaminated. Clean or replace the
Thermistor (PL 3.3.2,
).
Does the error persist?
Install a new Fuser (PL
3.3.36,
If the problem persists
Install a new Main PWB:
• Phaser 3330 (PL
1.0.7,
• WorkCentre 3335 and
List 6.1 WorkCentre
3335/3345 Main
).
Complete.
Summary of Contents for Phaser 3330
Page 3: ...Phaser 3320 and WorkCentre 3315 3325 Xerox Internal Use Only Service Manual 1 2...
Page 11: ...Contents Phaser 3330 and WorkCentre 3335 3345 Xerox Internal Use Only Service Manual x...
Page 409: ...Parts Lists Phaser 3330 and WorkCentre 3335 3345 Xerox Internal Use Only Service Manual 5 64...
Page 425: ...Wiring Data Phaser 3330 and WorkCentre 3335 3345 Xerox Internal Use Only Service Manual 7 6...
Page 431: ...Wiring Data Phaser 3330 and WorkCentre 3335 3345 Xerox Internal Use Only Service Manual 7 12...