XEROX DFC165 & DWC165c Service Manual
5-3
5.2
ERROR CODES
The error codes are
printed
on the journals (see section 5.3).
The format of these error codes, excluding those referring to the self-diagnostic test
(described in section 5.1.1), may be:
- one group of two digits (
xx
)
- two groups of two digits separated by a dot (
xx.xx
); this extended format:
•
indicates the
category
to which the error belongs, by means of the
first group
,:
01
Document incorrectly positioned
02
Unable to connect
03
No answer from correspondent
04
Failed transmission
05
Incomplete transmission
07
Document too long
08
Document jam
10
Failed or incomplete reception
11
No reception due to memory full
13
Failed polling reception
16
Power failure
•
provides
more detailed information
about the error, by means of the
second
group
, and may be requested by the technician with the machine in "service"
mode (see section 3.2.2), by setting
bit 0
of switch
SW09
to
1
(see section 4.1).
In the tables that follow, the error codes are indicated in their
extended format
and
in
ascending numeric order
.
For an explanation of the meaning of the protocol signal codes that appear in the
description of the causes of errors, see the next section (5.2.1).
Important
:
to ensure correct identification of the cause of the error, we recom-
mend you always print the communication protocol (PROTOCOL
DUMP, see section 5.2.3).