XEROX DFC165 & DWC165c Service Manual
4-3
4.1
SERVICE SWITCH TABLES
The tables that follow describe the functions carried out by the bits and combinations
of bits for each service switch. In order to correctly interpret some of the functions
required, a knowledge of the communication protocol is required. The default values
may undergo some modifications due to both homologation and user's peculiarities. For
this reason, you are recommended to print out the service switches of the facsimile
machine to be serviced, always before modifying them.
Switch SW01
bit
Function
set to 1
set to 0
7
Error code generated
YES
NO
on failed reception
Next page sent from the ADF
or resent from memory
6
despite bad reception signal
YES
NO
(RTN) from the receiver
Multifrequency
bit 5 4 =
0 0
, -11 / -9
5
output level
bit 5 4 =
0 1
, -8 / -6
4
(dBm)
bit 5 4 =
1 0
, -12 / -10
bit 5 4 =
1 1
, -10 / -8
Cable equalizer
bit 3 2 =
0 0
, 0 km (0 dB)
3
in reception
bit 3 2 =
0 1
, 1.8 km (4 dB)
2
(radius of cable = 0.4 mm)
bit 3 2 =
1 0
, 3.6 km (8 dB)
bit 3 2 =
1 1
, 5.6 km (12 dB)
Cable equalizer
bit 1 0 =
0 0
, 0 km (0 dB)
1
in transmission
bit 1 0 =
0 1
, 1.8 km (4 dB)
0
(radius of cable = 0.4 mm)
bit 1 0 =
1 0
, 3.6 km (8 dB)
bit 1 0 =
1 1