January 2016
2-26
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
04-800
Status Indicator RAPs
04-800 Duplex Fan 1 Locked RAP
04-800 The machine has detected a fault with duplex fan 1.
Procedure
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
Go to the relevant procedure:
•
4150 Checkout
•
4250/4260 Checkout
•
4265 Checkout
4150 Checkout
NOTE: The main PWB has test points. The location of the test points is shown on the
Main
PWB
PJ location illustration.
Refer to
Wiring Diagram 7
. Perform the following:
1.
Switch off the machine, then switch on the machine.
2.
Enter
dC330
code 04-400 and 04-410. Check that the duplex fan 1,
PL 7.35 Item 16
runs
at normal speed.
3.
Check the wiring between the duplex fan 1 and CN25 on the
Main PWB
.
4.
Install new components as necessary:
•
Duplex fan 1,
PL 7.35 Item 16
.
•
Side cover assembly,
PL 7.30 Item 1
.
5.
Perform the
OF5
Main PWB Check RAP.
4250/4260 Checkout
NOTE: The main PWB has test points. The location of the test points is shown on the
Main
PWB
PJ location illustration.
Refer to
Wiring Diagram 25
. Perform the following:
1.
Switch off the machine, then switch on the machine.
2.
Enter
dC330
code 04-400 and 04-410. Check that the duplex fan 1,
PL 7.35 Item 16
runs
at normal speed.
3.
Check the wiring between the duplex fan 1 and CN17 on the
Main PWB
.
4.
Install new components as necessary:
•
Duplex fan 1,
PL 7.35 Item 16
.
•
Side cover assembly,
PL 7.30 Item 1
.
5.
Perform the
OF5
Main PWB Check RAP.
4265 Checkout
NOTE: The main PWB has test points. The location of the test points is shown on the
Main
PWB
PJ location illustration.
Refer to
Wiring Diagram 41
. Perform the following:
1.
Switch off the machine, then switch on the machine.
2.
Enter
dC330
code 04-400 and 04-410. Check that the duplex fan 1,
PL 7.35 Item 16
runs
at normal speed.
3.
Check the wiring between the duplex fan 1 and CN31 on the
Main PWB
.
4.
Install new components as necessary:
•
Duplex fan 1,
PL 7.35 Item 16
.
•
Side cover assembly,
PL 7.30 Item 1
.
5.
Perform the
OF5
Main PWB Check RAP.
Summary of Contents for 4150 - WorkCentre B/W Laser
Page 1: ...January 2016 Xerox WorkCentre 4150 4250 4260 4265 Family Service Manual Updated 1 25 16 DAW...
Page 3: ...0 0 00 2 No Product Name Assigned Preliminary Working Document Section Name...
Page 5: ...January 2016 ii WorkCentre WorkCentre 4150 4250 42604150 4250 4260WorkCentre 4150 Introduction...
Page 415: ...January 2016 WorkCentre 4150 4250 4260WorkCentre 4150 4250 4260 4265WorkCentre Parts List...
Page 563: ...January 2016 7 2 WorkCentre WorkCentre 4150 4250 4260WorkCentre 4150 4250 Wiring Data...
Page 627: ...January 2016 8 2 WorkCentre WorkCentre 4150 4250 4260WorkCentre 4150 4250 Accessories...