January 2016
4-204
WorkCentre WorkCentre 4150/4250/4260WorkCentre 4150/4250/42604150/
ADJ 8.3
Repairs and Adjustments
ADJ 8.3 Lead Edge Registration Adjustment (4265)
Purpose
To measure and adjust lead edge image to paper registration.
Check
NOTE: Both the Check and the Adjustment use an internal test pattern. Both are performed in
diagnostics.
Check the lead edge registration (top edge of portrait A4 or 8.5x11 inch). Perform the following:
1.
Enter the Diagnostic mode (
GP 1
).
2.
Select Copier Information > dC 612 Print Test Pattern.
3.
Select test pattern 7.
4.
Select Plex Mode. For simplex lead edge check, select Simplex. For duplex lead edge
check select, Duplex.
5.
Select Start.
NOTE: Simplex copies exit face down. Duplex copies exit side 1 face down (side 2 face
up).
6.
Measure the distance between the lead edge of the paper and the ABC line on the printed
test pattern (
Figure 1
).
Figure 1 Test pattern 7
7.
If the distance measured is not 12.7mm (0.5 inch) +/-0.3mm (0.01 inches), perform the
Adjustment.
Summary of Contents for 4150 - WorkCentre B/W Laser
Page 1: ...January 2016 Xerox WorkCentre 4150 4250 4260 4265 Family Service Manual Updated 1 25 16 DAW...
Page 3: ...0 0 00 2 No Product Name Assigned Preliminary Working Document Section Name...
Page 5: ...January 2016 ii WorkCentre WorkCentre 4150 4250 42604150 4250 4260WorkCentre 4150 Introduction...
Page 415: ...January 2016 WorkCentre 4150 4250 4260WorkCentre 4150 4250 4260 4265WorkCentre Parts List...
Page 563: ...January 2016 7 2 WorkCentre WorkCentre 4150 4250 4260WorkCentre 4150 4250 Wiring Data...
Page 627: ...January 2016 8 2 WorkCentre WorkCentre 4150 4250 4260WorkCentre 4150 4250 Accessories...