REP 10.8 Fuser Connector (4250/4260)
Parts List on
PL 4.15
Removal
NOTE: This procedure should only be performed on the 4250/4260. For the 4150 or 4265 pro-
cedure, refer to the table of contents.
WARNING
Switch off the electricity to the machine. Disconnect the power cord from the customer
supply while performing tasks that do not need electricity. Electricity can cause death or
injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
CAUTION
Before performing this procedure, refer to General Disassembly Precautions,
GP 10
.
1.
Remove the exit guide assembly,
REP 10.2
.
2.
Remove the fuser assembly,
REP 10.1
.
3.
Prepare to remove the fuser connector,
Figure 1
.
Figure 1 preparation
4.
Remove the fuser connector,
Figure 2
.
Figure 2 Fuser connector
Replacement
Replacement is the reverse of the removal procedure.
2
Disconnect CON4 from power
supply unit 2.
1
Remove 2 screws.
3
Lift the fuser
connector cover.
1
Disconnect the white connector.
1
Remove 2 screws, then the
fuser connector from the cover.
Summary of Contents for 4150 - WorkCentre B/W Laser
Page 1: ...January 2016 Xerox WorkCentre 4150 4250 4260 4265 Family Service Manual Updated 1 25 16 DAW...
Page 3: ...0 0 00 2 No Product Name Assigned Preliminary Working Document Section Name...
Page 5: ...January 2016 ii WorkCentre WorkCentre 4150 4250 42604150 4250 4260WorkCentre 4150 Introduction...
Page 415: ...January 2016 WorkCentre 4150 4250 4260WorkCentre 4150 4250 4260 4265WorkCentre Parts List...
Page 563: ...January 2016 7 2 WorkCentre WorkCentre 4150 4250 4260WorkCentre 4150 4250 Wiring Data...
Page 627: ...January 2016 8 2 WorkCentre WorkCentre 4150 4250 4260WorkCentre 4150 4250 Accessories...