Connecting the Gas Pipe to the Fireplace:
Before the gas pipe can be connected to the fireplace, the Inlet Connection fitting and the
Inlet Test Point fitting must first be fitted to the appliance pressure regulator.
8.1
The fittings supplied with the fire need to be fitted to the pressure governor. A suitable joint
sealant and/or thread tape needs to be used on these unions.
The diagram below shows how to correctly assemble these two fittings to the pressure
regulator inlet side connection.
8.2
Soft copper should be run directly to fire and connected onto the regulator by means of an
8mm diameter compression fitting. An accessible inline isolation or service valve should
also be fitted. The regulator that is supplied with the fire MUST NOT BE REMOVED.
Removal of the regulator, or replacing it with one not intended for use with an XFIRE 1200,
will void the limited appliance warranty and could result in an unsafe installation.
9.0
Battery-Pack Power Supply:
The XFIRE 1200 runs on a battery pack. This battery pack uses 3x D cell batteries. To
ensure that only fresh batteries are used, batteries are not supplied with the fireplace.
These will be supplied by the installer.
To access the battery pack, remove the facia (described in section 17.0) and the battery
pack will be on the lower right hand side.
The Battery Pack is secured in place with Velcro pads and may be removed by firmly
pulling
upwards.