19.4
Switching off the XFIRE 1200:
To turn off the fire, push the OFF button, to shut down the gas flow to the fire and switch it
off. The OFF display will now appear in the display.
19.5
Setting the control mode for the fireplace:
There are three different modes for controlling the appliance:
> Manual
> Automatic
> Program
Automatic mode allows you to set a temperature, while in manual mode the flame level may
be set to HIGH, MEDIUM, LOW & PILOT. Program mode offers automatic temperature
control for specific times of the day.
In the initial screen when the remote is turned on, three options are available: AUTO,
MANUAL and MENU.
Auto and Manual are two of the three different modes for controlling the appliance with the
remote.
> Manual mode:
If Manual is pressed, Pilot appears as the selected
setting. In the bottom row,
↓
and
↑
appear, indicating that
the flame level can by changed by just pressing the left
or middle button. There are four possible flame positions:
Pilot flame, Low flame, Medium flame and High flame.
Pressing Back (right button), returns to the initial screen.
Note that a Safety temperature can be previously set in
the configuration menu. This specifies the maximum the
maximum permitted room temperature. This temperature
can never be set higher than 40ºC (104 ºF).
> Automatic mode:
If Auto is pressed in the initial screen, 25ºC (77 º F)
appears as the desired temperature in the selected
setting. In the bottom row,
↓
and
↑
appear, indicating that
we can change the desired temperature value by just
pressing the left or middle button. In auto mode the
appliance heats until this temperature is reached. Limits
are 0-37ºC (32-99ºF).
Pressing Back (right button), returns to the initial screen.
The Auto mode feature is optional and can be enabled or
disabled in the configuration menu (see specific chapter).
In this mode the main burner can be switched on and off.